SAFETY INSTRUCTIONS
Read this entire installation manual before beginning installation of the Aprilaire 6000 Series Zone Control System. For questions call Aprilaire
customer support at (800) 334-6011 or visit AprilairePartners.com.
WARNING
1. 120 volts may cause serious injury from electrical shock. Leave power disconnected until installation is complete.
2. The system is designed for indoor use only. Do not expose any of the components to moisture.
WARNING
1. Turn o the system power before removing or installing any wires into the terminals of any component of the system. Wiring with a live
circuit can lead to electrical shorts that can damage components.
2. Installation must be done in accordance with all applicable codes.
3. Installer should touch a grounded metal object before handling the components of the system. This will prevent any static discharge that
may cause damage.
4. A 6000 Series Zone Control System may not control temperature properly unless the heating and cooling system is properly sized and
balanced.
5. Insucient air flow or excessive temperatures through the heating and cooling system could result in equipment damage. Refer to the
manufacturer’s recommendations for minimum safe airflow and temperature requirements.
6. Do not mount the 6000 Series Control or Sensors on any exterior wall or equipment supply ductwork.
7. Do not install the system components where temperatures exceed 158°F (70°C) or are below 32°F (0°C), non-condensing.
8. Improper system installation could cause water damage from frozen pipes. Check system operation after installation.
READ AND SAVE THESE INSTRUCTIONS
6000 Series Zone Control System
For models 6010, 6015, 6020, 6025, 6030, 6035,
6040, 6045, 6045M
Safety & Installation Instructions
1
Question and Answer IconNeed help?

Do you have a question about the Aprilaire 6045M and is the answer not in the manual?

Aprilaire 6045M Specifications

General IconGeneral
CompatibilityAprilaire Humidifiers
BrandAprilaire
MPN6045M
Model6045M
Voltage24 VAC
MountingWall Mount
FeaturesAutomatic Humidity Control, Digital Display, Outdoor Temperature Sensor
Humidity Sensor Accuracy+/- 5% RH
Dimensions1.25" D
Weight0.5 lbs
Wire Size18 AWG

Summary

Safety Instructions

6000 Series Control Home Screen

6000 Series Hub Installation

6000 Series Hub Wiring

Temperature Sensors

HVAC Equipment Wiring Diagrams

Indoor Air Quality Wiring Diagrams

6000 Series Control and Sensors Installation

Location Recommendations

Guidelines for optimal placement of the control and sensors.

Mounting

Steps and instructions for physically mounting the control and sensors.

Control and Sensor Wiring

Installer Setup

Installer Setup Menu

Navigating the initial setup menu for system configuration.

Thermostat System Settings

Configuration options for thermostat modes, stages, and schedules.

Zone System Settings

Settings related to zone detection, staging, and temperature limits.

Indoor Air Quality (IAQ) Settings

Configuration for humidifier, dehumidifier, air cleaner, and ventilation.

Wi-Fi Setup

Installer Test Procedures

Sequence of Operation

Troubleshooting