Electrical system
RS 50
ch. 6
6-9
6
Release 00 2001-03
CHECK DATA
CHECKING THE GENERATOR
Disconnect the yellow wire from the regulator.
Start the engine and run it at 6000 rpm.
Using a tester in A.C. voltmeter mode, test the voltage
between:
generator yellow and ground wires = reading
greater than 35 V.
Using a tester in A.C. ammeter mode, test the current
between:
generator yellow and ground wires = reading
greater than 5 A.
CHECKING THE BATTERY
Voltage without load 12.5 ± 1 V.
Electrolyte density 1.26 at 20°C (68°F).
Check the electrolyte level, topping up with distilled
water if necessary.
Check that there are no signs of sulphation; replace if
necessary.
STARTER CIRCUIT
Location of components see (LOCATION OF COM-
PONENTS).
WIRING DIAGRAM
5) Battery
6) Starter relay
16) Starter button
34) Starter motor
G/R
M
B
+-
85
30
87
86
V/R
R
R
34
5
6
16
B
Positive
key-controlled