EasyManua.ls Logo

APV W+10/8 - 7 Service and Maintenance; Checking the Shaft Seal; Replacing the Shaft Seal

APV W+10/8
18 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GB
Form no.: L453147GB– revision 06/2013
7. Service and maintenance
7.1 Checking the shaft seal
Checkthepump'sshaftsealforleaksonaregularbasis.Iftheshaft
sealisleaking,replaceitoritsrelevantpartsasdescribedbelow.
7.2 Replacing the shaft seal
Thesectionaldrawing(page3)showsthepositionandconstruction
oftheshaftseal(applyingbothtoordinarysealsandsealswith
liquid/steamushing).
Toreplacetheshaftsealitisnecessarytodismantlethepump.
Followthestepsdescribedbelowandrefertothesectional
drawing(page3).
1. Disconnectthepowersupplyinthemotorisolatorbyremoving
thefusesanddisconnectingthecables.
2. Turnoffthesteamandushingliquidsupply.
3. Closethepumpsuctionanddischargepointanddrainthepump
housing.Ifthepumpisusedforhotand/oraggressiveliquids,
specialprecautionsmustbetaken.Insuchcases,observethe
localregulationsforpersonalprotectionwhenworkingwiththese
products.
4. Opentheclampring(item9a)orthehousingscrewsoncetheinlet
and outlet pipes have been properly isolated.
Dismantlethepumphousing(item1a,1b)andremovetheimpeller
(item4).
5. Takethestationarysealface(item5.6)installedinthebackplate
(item7a,7b)outwithyourngers.
6. Removetheo-ring(item5.5)fromthestationarysealface.
7. Useyourngerstoremovetherotarysealface(item5.7)ttedin
theimpeller(item4).
8. Removetheo-ring(item5.5)fromtherotarysealface.
9. Cleanthechambersofthestationaryandrotarysealfacewithair
or water.
9a Therearstationarysealface(item5.6)ismountedonthepressure
ring*(item5.11).Therotarysealface(item5.7)ismountedonthe
shaft(item11).Theseareremovedinthesamewayasthefront
sealcomponents.
*TheW+50/600pumphas2identicalpressurerings.
Dismantling the pump
Dismantling the shaft seal
11