3. Warnings
1. Readthroughtheinstructionsbeforeinstallingthepumpand
startingitup.Ifindoubt,contactyourlocalSPXFlowTechnology
representative.
2. Checkthatthespecicationsofthemotorandmotorcontrolunitare
correct.Thisappliesinparticulartoapplicationswhichcarryariskof
explosion.
3. Observethatapumpmaybeunstableandmaytilttotheforeontoits
inlet port when having a relatively small motor and being assembled
onbracketsinsteadofbeingequippedwithaframewithadjustable
feet.Becarefulduringtheinstallationofsuchapump.(Forthis
reason, the W+50/600 pump is equipped with an anti-tilting unit.)
4. Donotstartthepumpbeforeallpipeconnectionshavebeentted
carefullyandtightened.Specialprecautionsmustbetakenwhen
thepumpisusedtopumphotand/orhazardousliquids.Insuch
casesfollowthelocalregulationsforpersonalsafetywhenworking
withtheseproducts.
5. Donotstartthepumpbeforethemotorshroudorshaftguardhasbeen
securelytted.
6. Thepumpcontainsrotatingparts.Neverputyourhands,ngersor
objectsintoapumpwhileitisinoperation.
7. Nevertouchtheshroudduringoperation,asitcanbecomeveryhot.
8. Nevertouchthepumpbodyduringoperationifthepumpisbeingused
forhotmedia,asthereisariskofbeingburnt.
9. Ifthepumpisoperatingwithliquidmediabuthasnocirculation,the
liquidwillheatupandmayturnintovapour,whichcouldcausean
explosion.
10. Alwaysremoveallassemblyandauxiliarytoolsfromthepumpbefore
starting it up.
11. Neverhosedownorcleantheelectricmotordirectlywithwater
orcleaninguid.
12. Neverliftthepumpattheshroud,asitisnotdesignedtocarrythe
weightofthemotor.Removetheshroudbeforeliftingthepump.
Alwaysusesecurelyttedliftingstrapswhenliftingwithacrane
orsimilarliftinggear.
13. Neverdismantlethepumpbeforethemotorhasbeendisconnected
fromthepowersupply.Removethefusesanddisconnectthecable
fromthemotorterminalbox.
14. Theinstallationofallelectricalpartsmustbecarriedoutbyqualied
personnel.