MR. SILENCE
INVERTER POOL HEAT PUMP
USER MANUAL

Questions and Answers

  • M
    Michelle BennettAug 10, 2025
    Why is my AQUARK MR.SILENCE MS170 fan running but not heating?
    • N
      Nicole HicksAug 10, 2025
      If your AQUARK Heat Pump's fan is running but not providing enough heat, check for these possible causes: * **Blocked evaporator:** Make sure there are no obstructions blocking the evaporator. * **Blocked air outlet:** Ensure that the air outlet is free from any obstacles. * **Start delay:** The unit may have a 3-minute start delay. If this is the case, wait patiently for the heating to begin.
  • A
    Adam LongAug 19, 2025
    What to do if AQUARK MR.SILENCE MS170 Heat Pump doesn’t run?
    • C
      Craig OdonnellAug 19, 2025
      If your AQUARK Heat Pump isn't running, the following could be the reasons: * **No power:** There might be a power outage. Wait for the power to be restored. * **Power switch is off:** Ensure that the power switch is turned on. * **Fuse burned:** Inspect the fuse and replace it if necessary. * **Breaker is off:** Check the breaker and switch it on if it has tripped.
  • J
    Jeffrey DickersonAug 29, 2025
    What to do if my AQUARK MR.SILENCE MS170 Heat Pump display is normal, but there is no heating?
    • J
      Julie EspinozaAug 29, 2025
      If your AQUARK Heat Pump display is normal, but there's no heating, consider the following: * **Set temperature:** The set temperature might be too low. Adjust it to a suitable heating temperature. * **Start delay:** There could be a 3-minute start delay. If this is the case, wait patiently.

Summary

Safety Precautions

Warnings

Highlights hazards and critical procedures for preventing personal injury or third-party harm.

Important Cautions

Details essential precautions like ventilation, placement away from fire, and professional repair requirements.

General Safety Guidelines

Provides instructions on power handling, lightning protection, ventilation, and refrigerant safety during installation and repair.

Installation Guidance

Installation Reminders

Emphasizes that installation must be performed by professional staff only for safety and unit integrity.

Wiring Instructions

Covers connecting to power supply, earthing, professional wiring, and leakage protector settings.

Electric Wiring Diagram

Illustrates the electrical connections for the heat pump, specifying voltage and frequency requirements.

Operation Guidance

Operation Instructions

Details how to use the control panel: screen lock, power on/off, temperature setting, and mode selection.

Testing Procedures

Leakage Detection

Provides guidelines and methods for detecting refrigerant leaks safely, including prohibited actions and materials.

Maintenance

Troubleshooting Common Faults

Repairing Guidance and Personnel

Provides warnings and requirements for qualified service personnel and safe repair practices.

Failure Solutions and Codes

Lists common failures, their reasons, solutions, and protection/failure codes for diagnosis.