UV Lamp Replacement And/Or Cleaning:
WARNING! Regularly inspect your disinfection system unit to ensure the UV
light is still glowing. Replace the UV lamp annually to ensure a high bacteria
and virus kill rate.
IMPORTANT! During the assembly and handling of the quartz sleeve and or
UV Lamp it is recommended to wear plastic gloves. DO NOT touch the quartz
or UV lamp with bare hands. Fingerprints can reduce the performance of the
UV lamp.
1. Disconnect the power
2. Shut off water supply and drain all lines.
3. Pull the UV lamp off of the chamber while it is still connected to
the ballast line.
4. Disconnect the old UV lamp from the ballast.
5. Connect the ballast plug to the new UV lamp electrical prongs.
6. Reinsert the lamp back into the chamber carefully.
7. Turn on the water supply and check for leaks.
8. Reconnect the power
Note: If the system is put on a temporary hold, bypassed, removed,
or if it becomes contaminated after the disinfection system, It will be
necessary to shock the system with household bleach for a full 20
minutes before resuming use of the water.