16
Quartz Sleeve Replacement And/Or Cleaning:
If the water contains any hardness minerals (calcium or magnesium), iron or
manganese, the quartz sleeve will require periodic cleaning. To remove the quartz
sleeve, rst the UV lamp as outlined above:
1. Shut off water supply and drain all lines.
2. Drain the UV chamber (use a small bucket under the unit to prevent a
spill), using drain port provided.
3. Remove nuts from chamber, checking for the free oating spring inside
sleeve at the opposite end to the lamp connection (do not allow quartz
sleeve to fall).
4. Carefully remove O-rings from the quartz sleeve. As the O-ring may
tend to adhere to the quartz sleeve, it is recommended to replace the
O-rings annually.
5. Clean the quartz sleeve with a cloth soaked in CLR, vinegar or some
other mild acid and then rinse avoiding the introduction of any water to
the inside of the sleeve.
6. Re-assemble the quartz sleeve with spring in the UV chamber allowing
the sleeve to protrude an equal distance from chamber.
7. Wet the O-rings and slide onto each end of the quartz sleeve.
8. Reassemble the gland nuts (hand tight is sufcient).
9. Re-tighten all connections, turn on water and check for leaks.
Re-install the UV lamp and lamp connector as per prior instructions
10. Reconnect system to power source.
Note: If the system is put on a temporary hold, bypassed, removed,
or if it becomes contaminated after the disinfection system, It will be
necessary to shock the system with household bleach for a full 20
minutes before resuming use of the water.