SERVICE MANUAL
Model
47L(50 qrt)
35L(37 qrt)
60L(63 qrt)
78L(82 qrt)
Type
10800010
10800020
10800030
10800040
Date
December 2014

Table of Contents

Questions and Answers

  • M
    Ms. Crystal SampsonSep 12, 2025
    What does “Err2” mean on my ARB 60L's display?
    • L
      larsonjonathanSep 12, 2025
      If your ARB Refrigerator's digital display shows “Err2”, the thermistor circuit is ‘short circuit”. Test the thermistor and replace it if necessary.
  • J
    Janet HensleySep 12, 2025
    What does “Err1” mean on my ARB 60L Refrigerator's display?
    • L
      lisacarterSep 12, 2025
      If your ARB Refrigerator's digital display shows “Err1”, the thermistor is not correctly connected to the control panel circuit board; check its connection. Alternatively, the thermistor circuit may be ‘open circuit’; test the thermistor and replace it if necessary.
  • M
    Michael SuttonSep 10, 2025
    Why does the lid of my ARB 60L open while driving?
    • D
      david40Sep 10, 2025
      If your ARB Refrigerator's lid opens during transit, first, ensure that the latch was correctly closed before transportation. If the issue persists, inspect the latch and latch pivot for damage, and replace the latch assembly if necessary, as the latch may be faulty.
  • S
    shannon67Sep 9, 2025
    Why is the latch on my ARB 60L Refrigerator hard to disengage?
    • J
      Justin OconnorSep 9, 2025
      If the latch on your ARB Refrigerator does not easily disengage from the lid, it could be due to the high-quality seal causing the lid to sit away from the fridge cabinet; press down slightly on the lid to help disengage the latch. Alternatively, the latch itself may be faulty; inspect the latch and latch pivot for damage, and replace the latch assembly if necessary.
  • S
    Steven JonesSep 8, 2025
    Why is my ARB 60L Refrigerator not reaching the set temperature?
    • C
      cdavisSep 8, 2025
      If your ARB Refrigerator does not reach the target temperature, it might be operating at its maximum cooling capacity in extreme ambient temperatures. The maximum cooling capability of the system is a reduction of 50°C (122°F) below the ambient temperature.
  • K
    Kevin MurphyAug 23, 2025
    What to do if my ARB 60L runs but does not cool?
    • A
      Amy WilliamsAug 23, 2025
      If your ARB Refrigerator does not cool but the compressor runs, ensure there is sufficient clearance around the fridge and that the fan is not obstructed to provide proper ventilation. Check that the correct battery protection setting is selected. Inspect the lid seal for damage or if it's missing, and replace it if necessary. Also, look for any visible oil leaks around the refrigeration lines, compressor, and condenser. If you detect a leak or suspect a blockage within the refrigeration system, contact a qualified refrigeration mechanic for assistance.
  • S
    Steven HunterSep 6, 2025
    Why does my ARB Refrigerator have an intermittent power supply?
    • S
      Shelley HuangSep 6, 2025
      If you are experiencing intermittent power supply to your ARB Refrigerator, it could be due to a poor connection of the plug into the socket at the back of the fridge, or a poor connection of the plug into the supply socket. Check that both plugs are correctly installed. It's also possible that the compressor has stopped running because the battery cut-out voltage has been reached. Ensure the correct battery protection setting is selected and that the vehicle wiring is adequate.
  • G
    Grace MartinSep 5, 2025
    Why won't my ARB 60L Refrigerator run when the voltage is above 13.8V?
    • J
      Julia CameronSep 5, 2025
      If your ARB Refrigerator will not run when the DC input voltage exceeds 13.8V, the main circuit board may be faulty. Replace the main circuit board and retest to resolve the issue.
  • J
    Jane AcevedoSep 4, 2025
    What does it mean when the error light flashes twice on my ARB 60L?
    • R
      robertobrownSep 4, 2025
      If your ARB Refrigerator does not run, and the error light flashes twice every 5 seconds, it could be due to a few reasons. The fan might not be correctly connected to the compressor control unit, so check the fan wiring to ensure the "+ve" and "–ve" fan wires are properly connected. Alternatively, the fan itself could be faulty, in which case you should test and replace it if necessary. Lastly, the compressor control unit might be faulty, requiring testing and potential replacement.
  • A
    Antonio HardinSep 3, 2025
    Why does the device fuse in my ARB 60L keep blowing?
    • L
      Lindsey MorrisonSep 3, 2025
      If your ARB Refrigerator's device fuse repeatedly blows, it could be due to a short circuit in the 100-240V AC fridge cable. Check the cable's continuity and replace it if it's faulty or damaged. Another cause could be a short circuit between the "L" and "N" terminals on the compressor control unit; check for this. Lastly, an unregulated or fluctuating power supply, such as from an engine-driven generator, might be the issue. Ensure the generator has a voltage regulator and supplies a standard, pure sine wave AC voltage without fluctuations.

Summary

2 WARRANTY

2.1 ARB Fridge Freezer Limited Warranty

Details the terms, conditions, and exclusions of the limited warranty.

3 STANDARD SERVICE;WARRANTY TIMES

6 TROUBLESHOOTING

6.1 Check (diagnosis) lights

Explains troubleshooting by interpreting diagnostic error light flash codes.

6.2 DC Power Supply

Guides on diagnosing issues related to 12/24V DC power input to the fridge.

6.3 AC Power Supply

Provides troubleshooting steps for problems with 100-240V AC power supply.

6.4 Cooling

Addresses issues related to the fridge not cooling or cooling incorrectly.

6.6 Battery Protection Settings

Explains the three battery protection modes and how to adjust them.

7 FAULT FINDING FLOW CHARTS

7.1 Fridge will not run on 100-240 V AC power

A flowchart to diagnose why the fridge won't run on AC power.

7.2 Fridge will not run on 12;24 V DC power

A flowchart to diagnose why the fridge won't run on DC power.

8 CHECKS AND TESTS

8.1 Vehicle wiring system

Details how to test the vehicle's wiring system for voltage drop.

8.2 Test compressor control unit - 12;24 V DC

Procedure to test the compressor control unit's operation on DC power.

8.3 Test main circuit board - 100-240 V AC

Procedure for testing the main circuit board's AC power section.

8.4 Test compressor control unit - 100-240 V AC

Procedure to test the compressor control unit's operation on AC power.

8.5 Test compressor

Tests the internal compressor windings for resistance.

8.6 Test thermistor

Details how to test the thermistor's resistance value.

9 SERVICE

9.1 Control panel circuit board - Replace

Step-by-step instructions for replacing the control panel circuit board.

9.3 Compressor control unit - Replace

Procedure for replacing the compressor control unit.

10 SERVICE BY REFRIGERATION MECHANIC