EasyManua.ls Logo

ARC FLEX 8EX - Special Pushbutton Functions

ARC FLEX 8EX
46 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Flex 8ES/EX Standard, AB and Tandem Instruction Manual (CE)
November 2016
Page 24 of 45
F1 F/R2R1 R1F1 F/R2
F1 R1 F2 R2R2F2R1F1
R2F2R1F1 R2F2R1F1
Fwd Rev
Slow
FastFwd Rev
Slow
Fast
4.2.2.2 Output Relay Actions at 2
nd
Speed (Flex 8EX only)
1. 3 output relays configuration with Closed/Closed contact at 2
nd
speed
F1 (or R1) output relay closed at 1
st
speed and F1 + F/R2 (or R1 + F/R2) output
relays closed at 2
nd
speed. Refer to section 4.2.3.1 on how to set to this function.
Forward 1
st
speed pushbutton pressed Forward 2
nd
speed pushbutton pressed
2. 4 output relays configuration with Opened/Closed contact at 2
nd
speed
F1 (or R1) output relay closed at 1
st
speed and F2 (or R2) output relay closed at 2
nd
speed. Refer to section 4.2.3.1 on how to set to this function.
Forward 1
st
speed pushbutton pressed Forward 2
nd
speed pushbutton pressed
3. 4 output relays configuration with Closed/Closed contact at 2
nd
speed
F1 (or R1) output relay closed at 1
st
speed and F1 + F2 (or R1 + R2) output relays
closed at 2
nd
speed. Refer to section 4.2.3.1 on how to set to this function.
Forward 1
st
speed pushbutton pressed Forward 2
nd
speed pushbutton pressed
4. 4 output relays configuration with Slow and Fast output relays (Type A)
Fwd (or Rev) + Slow output relays closed at 1
st
speed and Fwd (or Rev) + Fast output relays
closed at 2
nd
speed. Refer to section 4.2.3.1 on how to set to this function.
Forward 1
st
speed pushbutton pressed Forward 2
nd
speed pushbutton pressed

Table of Contents