7.4 Environment
Operational temperature
Sensor head
-40°C / +75°C
Display - standard
- IP67
-20°C / +70°C
-10°C / +60°C
Processing Unit
-40°C / +68°C
Storage temperatures
Sensor head
-40°C / +75°C
Display - standard
- IP67
-30°C / +80°C
-20°C / +70°C
Processing Unit
-40°C / +75°C
Cold / hot start
Sensor head
-40°C / +75°C
Display
-20°C / +70°C
Processing Unit
-40°C / +68°C
Vibrations according to IEC 60068-2-64
Sensor head
ISO 16750 § 4.4 g=57,9m/s
2
Processing Unit
ISO 16750 § 4.4 g=57,9m/s
2
Shocks according
Sensor head
ISO 16750
IEC 60068-2-29: 500m/s2 during 6ms
IEC 60068-2-27: Bump, test Eb : 40g for 6ms
Processing Unit
ISO 16750
IEC 60068-2-29: 500m/s2 during 6ms
IEC 60068-2-27: Bump, test Eb : 40g for 6ms

Other manuals for ARCURE BLAXTAIR 3