Installation and Operator's Manual for RSM series of Modular Switched Mode Rectifiers
Table of Contents
1.0 Warranty
2.0 Documentation - Part number information...............................................................................................1
2.1 Introduction..................................................................................................................................1
2.2 ARGUS Numbering system ........................................................................................................1
3.0 General.....................................................................................................................................................2
3.1 Scope ..........................................................................................................................................2
3.2 Introduction..................................................................................................................................2
3.3 Features ......................................................................................................................................2
3.3.01 LCD Display and Control Keys ......................................................................................2
3.3.02 Status Mode Indicators ..................................................................................................6
3.3.03 Status Indicator - Module OK ........................................................................................6
3.3.04 Status Indicator - Alarm Condition Present ...................................................................6
3.3.05 Status Indicator - Micro-Controller Fail / Reset .............................................................6
3.3.06 Module Fail Indicator......................................................................................................6
3.3.07 Float Mode .....................................................................................................................7
3.3.08 Equalize Mode ...............................................................................................................7
3.3.09 Test Mode ......................................................................................................................7
3.3.09.1 Manual test .................................................................................................7
3.3.09.2 Auto test - units without High Output Alarm feature: .................................7
3.3.09.3 Auto test - units with High Output Alarm feature: ......................................8
3.3.10 Alarms ............................................................................................................................8
3.3.11 True Module Fail Alarm .................................................................................................9
3.3.12 Low Voltage Alarm ........................................................................................................9
3.3.13 HighVoltage Alarm ........................................................................................................9
3.3.14 Current Limit...................................................................................................................9
3.3.15 Over Voltage Shutdown .................................................................................................10
3.3.16 Remote Equalize............................................................................................................10
3.3.17 Remote Shutdown..........................................................................................................10
3.3.18 Automatic High Voltage Shutdown Restart ...................................................................10
3.3.19 Start Delay .....................................................................................................................11
3.3.20 Soft Start ........................................................................................................................11
3.3.21 Slope or Forced Paralleling ...........................................................................................11
3.3.22 Input / Output Circuit Breakers ......................................................................................11
3.3.23 A.C. High / Low Voltage Shutdown ...............................................................................12
3.3.24 Demand Based Forced Cooling.....................................................................................12
3.3.25 Battery Eliminator Operation..........................................................................................12
3.3.26 Remote or Local Sensing ..............................................................................................12
3.3.27 Micro-controller Reset ....................................................................................................12
3.3.28 Output Voltage Test Points............................................................................................13
3.3.29 Remote monitoring.........................................................................................................13
3.3.30 A.C. Inrush / Transient Suppression..............................................................................13
3.3.31 Control Fail Safe & Memory ..........................................................................................13
3.3.32 Over Temperature Alarm ...............................................................................................13
3.3.33 Over Temperature Shutdown.........................................................................................13
3.3.34 UPF Heatsink Over Temperature Alarm........................................................................13
4.0 INSTALLATION INSTRUCTIONS............................................................................................................14
4.1 Tools Required............................................................................................................................14
4.2 Inspection ....................................................................................................................................14
4.3 Preparation/Mounting ..................................................................................................................14
4.3.1 3 Module Shelf ...............................................................................................................15
4.3.2 4 Module Shelf ...............................................................................................................15