The commands must be entered correctly the first time. The backspace and delete and other com
-
mon editing keys will NOT work. If you wish to terminate an incorrect command and re-enter it,
simply enter ']' and start over. The command, if it is invalid, will be ignored.
For ease of use, macros are usually programmed in the terminal program used and assigned to the
function keys (or other available keys).
The following keys have been preset in the LYNC configuration and they can be changed to suit the
individual user's requirements. The default key assignments are are as follows:
F1 [01
F2 [02
F3 [03
F4 [04
F5 U]
F6 S]
F7 D]
F8 E]
Note that the macros can be split between keys for flexibility. Using the above macros, the user
would press F1 and then F6 to get the status of unit # 01, and similiarly, F2 and F6 for the status of
unit #02.
If you change the baud rate of the module using a locally connected terminal (ie not via modem),
then you will have to change the baud rate of the terminal to match the module's new setting. Do
this immediately after sending the “ENTER” command (“[##E]”) to be able to continue the session.
DO NOT CHANGE THE MODULE BAUD RATE IF YOU ARE CONNECTED BY MODEM UNLESS
YOU ARE ABLE TO CHANGE THE MODEM PORT BAUD RATE REMOTELY AS WELL.
8.1.6 Access to the RSM
There are two distinct levels of communications possible with the RSM.
8.1.6.1 Remote Access/Lockout
When remote communications are locked out the RSM ignores all commands and responds only
with REMOTE LOCKOUT.
When remote communications are enabled the level of communication is determined by the status
of REMOTE ADJUST.
To change the status of REMOTE ACCESS/LOCKOUT, select the REMOTE COMMUNICATIONS
menu item. You will be prompted for the security code before any adjustments can be performed.
REMOTE ACCESS/LOCKOUT is the first item inside the REMOTE COMMUNICATIONS menu.
Pressing the Enter/Select key toggles between REMOTE ACCESS and REMOTE LOCKOUT.
8.1.6.2 Remote Adjust Access/Lockout
When REMOTE ADJUST is locked out, the RSM simply ignores the UP, DOWN, and ENTER com
-
mands and responds with REMOTE LOCKOUT. The module will only provide status information
through the STATUS command.