ADJUSTMENTS .............................................enter adjustments menu
ADJ^^^^ EQLIZE V .......................................adjust equalize voltage
ADJ^^^^ FLOAT V ........................................adjust float voltage
ADJ^^^^ HV SHUTDN ...................................adjust output high voltage alarm value
AUTO TEST ...................................................starts auto test mode
BACKLIGHT TIMEOT ....................................enter backlight timeout adjustment
BAUD RATE ..................................................enter baud rate setting
BAUD RATE = 1200/2400/4800/9600 ...........adjust baud rate value
BKLT TO = XXmin .........................................display/adjust backlight timeout
CUR LIM = XX.XA .........................................display/adjust current limit
CURRENT LIMIT ...........................................enter current limit adjustment
DELAY = XXXsecs ........................................adjust start delay time
DISPL CALIBRATE ........................................adjust voltage display calibration
EQ TIMEOUT .................................................enter equalize timeout adjustment
EQ TMOUT = XXhrs ......................................display/adjust equalize timeout
EQUALIZE = XX.XV ......................................display equalize voltage
EQUALIZE VOLTAGE ...................................enter equalize voltage adjustment
EXIT ...............................................................return to regular display
*FAN SET = OFF/LOW/MED/HIGH ..............display fan setting
**FAN SET = OFF/ON ...................................display fan setting
*FAN SPEED = OFF/LOW/MED/HIGH .........display fan speed
**FAN SPEED = OFF/ON ...............................display fan speed
FLOAT = XX.XV ............................................display float voltage
FLOAT VOLTAGE .........................................enter float voltage adjustment
FORCE SHAR DISAB/ENABL .......................display/adjust current share setting
HIGH O/P = XX.XV .........................................display/adjust output high voltage alarm value
HIGH O/P ALARM ..........................................enter output high voltage alarm value
HSNK TEMP = XXXC/XXXF .........................display heatsink temperature
***HV SD LEVEL ADJ.....................................enter output high voltage shutdown level
***HV SD = XX.XV ..........................................display output high voltage shutdown level
I LIM ALRM ENAB/DISAB .............................display/adjust current limit alarm setting
I/P V = XXXVAC ............................................display AC input voltage
INT AMB TP = XXXC/XXXF ..........................display internal ambient temperature
LCL ACC ALM ENAB/DISAB ........................display/adjust local access alarm setting
LOAD SHARING ............................................enter current sharing menu
LOW O/P = XX.XV ........................................display/adjust output low voltage alarm value
LOW O/P ALARM ..........................................enter output low voltage alarm setting
MANUAL TEST ..............................................starts manual test mode
MODULE ID ...................................................enter module id# setting
MODULE ID = XX ..........................................adjust module id #
MODULE SETTINGS .....................................enter module settings menu
O/P HV = XX.XV ............................................display output high voltage shutdown level
O/P HV LEVEL ADJ ......................................enter output high voltage shutdown setting
OPEN O/P BREAKER ...................................open output breaker if not already open
PROTECTED ADJUST ..................................enter security controlled menu
REMOTE ACCESS/LOCKOUT .....................display/adjust remote access setting
REMOTE COMMUNIC ..................................enter remote communications menu
RETURN ........................................................return to previous menu
SECURITY = —- ............................................enter security code for access
SECURITY CODE = —- ................................adjust security code
SET SECURITY CODE .................................enter security code adjustment
SLOPE ...........................................................enter slope adjustment
SLOPE = X.XX% ...........................................display/adjust slope value
SOFTWARE V X.XX ......................................display software version number
START DELAY ..............................................enter start delay time adjustment
STATUS .........................................................enter status menu
STRT DELAY = XXXsec ...............................display start delay time
TEMP DISPL DEG C/F ..................................adjust temperature display mode
TEST MODE ..................................................enter test mode menu
Possible Menu Prompts:
AC MAINS FAIL
AC MAINS HIGH
CURRENT LIMIT
FAN FAIL
*FAN SPEED ERROR
HIGH O/P VOLTAGE
I/P BREAKER OPEN
LOW O/P VOLTAGE
MODULE FAIL
***NO OUTPUT POWER
O/P BREAKER OPEN
O/P HV SHUTDOWN
OVER TEMPERATURE
REMOTE EQUALIZE
REMOTE SHUT DOWN
START DELAY = XXX
TEMP SENSE FAIL
THERMAL SHUTDOWN
***UPF TEMP
* - RSM 48/50 and RSM 24/100
** - RSM 48/30 and RSM 24/50
*** - RSM 48/50 UPF and
RSM 24/100 UPF
Possible Alarm & Mode
Messages
Table 1 - Display Messages