11 - 38
2 sets of contacts, one normally open, one normally closed. Contact resistance is 0.1-0.3 ohms when correct.
Normally open contacts manually activated. Contact
Resistance is 0.1-0.3 ohms when correct.
Pins 85-86 coil resistance 87-100 ohms. pins 30-87 normally open. Pins 30-87A normally open. Contact resistance
is 0.1-0.3 ohms when correct.
(A) When PTO switch is on.
Pins 85-86 coil resistance 87-100 ohms. pins 30-87 normally open. Pins 30-87A normally closed. Contact
resistance is 0.1-0.3 ohms when correct.
(A) With neutral switch engaged and PTO switch off.
PTO Switch Off Run Start
Brown 11.50-13.00 Volts
Purple 11.50-13.00 Volts 11.50-13.00 Volts
Red/Green 11.50-13.00 Volts 11.50-13.00 Volts
Brown/Yellow 11.50-13.00 Volts
Neutral Switch Off Run Start
Brown/Yellow 11.50-13.00 Volts
Red/Green 11.50-13.00 Volts 11.50-13.00 Volts
PTO Relay Off Run Start
Green/White 86 11.50-13.00 Volts(A) 11.50-13.00 Volts(A)
Black/White 85 Connected to ground when start relay
energized
Purple/White 87 11.50-13.00 Volts 11.50-13.00 Volts
87A Not Used Not Used
Purple 30 11.50-13.00 Volts 11.50-13.00 Volts
Start Relay Off Run Start
Red/Yellow 86 11.50-13.00 Volts(A) 11.50-13.00 Volts(A)
Black 85 Connected to Ground
Black/White 87
White/Black 87A Connected to Ignition Module
Black 30 Connected to Ground