“THERMAL DISINFECTION CYCLE” FUNCTION ANTILEGIONELLA
The antibacterial function is activated by pressing the MODE button for 3 seconds. All the temperature LEDS are
switched o during activation, with the sole exception of the 60° LEDS, which ash. Similarly, all the LEDS switch o
during deactivation, with the exception of the 40° LED, which ashes.
The antibacterial function heats the water to avoid the formation of bacteria in the internal tank. The antibacterial
function is performed when the machine is switched on (with supercap empty) or 30 days (depending on the NFC
parameter settings) after the last time that the antibacterial condition was considered to be satised: this occurs when
the average water temperature has been higher than the antibacterial setpoint for a certain period (this depends on
the NFC, but the antibacterial cycle is usually performed at 65° C to guarantee that the temperature is higher than 60°
C for 1 hour).
TECHNICAL CHARACTERISTICS
For the technical specications, refer to the nameplate (the nameplate is located next to the water intake/outlet pipes).
Table 1 - Product information
Product range 50 80 100
Weight (kg) 17 22 26
Installation
Vertical Vertical Vertical
Model Refer to the nameplate
SMART X X X
Qelec (kWh) 6,893 7,323 7,455
Qelec, week, smart (kWh) 24,558 25,435 26,002
Qelec, week (kWh) 29,678 32,942 33,778
Load prole M M M
L
wa
15 dB
wh
40,0% 40,0% 40,0%
V40 (L) 65 92 130
Capacity (l) 49 75 95
The power consumption data in the table and the other information given in the Product Data Sheet (Enclosure A to this
manual) are dened in relation to EU Directives 812/2013 and 814/2013.
The products without the label and the data sheet for water heaters and solar devices, stipulated in regulation 812/2013,
are not intended to be used in such assemblies.
The device is equipped with a smart function that allows you to adapt the consumption to the user proles. If operated
correctly, the device has a daily consumption of “Qelec* (Qelec,week,smart/Qelec,week)” less than that of an
equivalent
product with no smart function.
This appliance is conforming with the international electrical safety standards IEC 60335-1 and IEC 60335-2-21.
The CE marking of the appliances attests its conformity to the following EC Directives, of which it satises the
essential requisites:
- LVD Low Voltage Directive: EN 60335-1, EN 60335-2-21, EN 60529, EN 62233, EN 50106.
- EMC Electro-Magnetic Compatibility: EN 55014-1, EN 55014-2, EN 61000-3-2, EN 61000-3-3.
- RoHS2 Risk of Hazardous Substances: EN 50581.
- ErP Energy related Products: EN 50440.
This product is in conformity with REACH regulations.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ariston 100 Series and is the answer not in the manual?

Ariston 100 Series Specifications

General IconGeneral
Voltage230 V
Frequency50 Hz
Heating ElementCopper
Capacity100 L
Maximum Working Pressure8 bar
Tank MaterialEnameled steel
InsulationPolyurethane