Ariston AURES Slim Multi - Installation Requirements

Ariston AURES Slim Multi
11 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2. Be sure to every so often clean the spray head of sediment to assure a smooth water flow.
3. Be sure to every so often clean the incoming water filter.
4. Be sure to install your Instant Water Heater in a heated location. The appliance cannot be
installed in areas where the temperature may drop critically and there may be a risk that ice may
form.
5. The user can adjust the hot water temperature regulating the setting power on the unit. the user
can choose till 4 setting poer position:
Power – Heating element is off
Low – Only the 1st Heating element switches on.
Med – Only the 2nd heating element switches on.
High – 1st and 2nd heating elements switch on, working together.
INSTALLATION REQUIREMENTS
A separate electrical line is required.
B. The device must be connected to a separate circuit breaker.
C. The recommended electrical cable for feeding the device, see table I (next page).
INSTALLATION
Device with 220-240V from 7kW up to 12kW & 400-415V 3 Phase
WARNING!
BEFORE BEGINNING ANY WORK ON THE ELECTRICAL INSTALLATION BE SURE THAT THE CIRCUIT
BREAKER IS IN THE “OFF” POSITION TO AVOID DANGER OF ELECTRICAL SHOCK