EasyManuals Logo

Ariston CLAS EVO SYSTEM 24 CF Training Manual

Ariston CLAS EVO SYSTEM 24 CF
69 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #26 background imageLoading...
Page #26 background image
Training manual CLAS X
Pag. 26 di 69
3 WAY VALVE MOTOR DISASSEMBLY:
Before disassembly the 3 way valve is mandatory remove the stepper motor.
To remove the stepper motor the 3 way valve must be in DHW or stand-by position, otherwise it is not
possible remove it. To do this it is enough switch off the boiler throught the ON/OFF button.
- Remove the motor blocking ring, rotating clockwise.
- Unblock the stepper motor
BLOCKED UNBLOCKED