Training manual CLAS X
Pag. 54 di 69
6 ELECTRIC AND ELECTRONIC SYSTEM
6.1 MAIN CARD
The boiler uses a GALEVO2 SE electronic card for complete checking of the boiler and one users interfaces
display LCD;
The GALEVO2 SE electronic card is protected by two 2A, 250 VAC fuses and a VDR protects the card
against supply voltage peaks up to 275VAC. The supply voltage tolerance is 230 Vac +10% -15% and
does not have to comply with the phase and with neutral.