EasyManua.ls Logo

Ariston CLAS EVO SYSTEM 24 CF - Menù 8: Service Parameters

Ariston CLAS EVO SYSTEM 24 CF
69 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Training manual CLAS X
Pag. 64 di 69
7.2.7 Menù 8 : Service parameters
Menù
Sub Menù
Parameter
Function
Range
Default
setting
8
0
BOILER STATISTICS
8
0
0
Diverter valve cycles (nr x 10)
(only visualization)
/
8
0
1
Time of circulator on (h x 10)
(only visualization)
/
8
0
2
Boiler circulator cycles (nr x 10)
(only visualization)
/
8
0
3
Boiler Life Time (h x 10)
(only visualization)
/
8
0
4
Time of fan ON (h x 10)
(only visualization)
/
8
0
5
Number of fan cycles (nr x10)
(only visualization)
/
8
0
6
Number of flame detection in
CH (nr x10)
(only visualization)
/
8
0
7
Number of flame detection in
DHW (nr x10)
(only visualization)
/
8
1
BOILER STATISTICS
8
1
0
Hours burner on in heating (h x
10)
(only visualization)
/
8
1
1
Hours burner on in sanitary (h x
10)
(only visualization)
/
8
1
2
Number of flam lifts
(n x 10)
(only visualization)
/
8
1
3
Number of ignition cycles
(n x 10)
(only visualization)
/
8
1
4
Average heat request duration
(h x 10)
(only visualization)
/
8
2
BOILER
8
2
0
Burner modulation
0 ÷ 255 (only visualization)
/
8
2
1
Fan state
0: Off ; 1: On (only visualization)
/
8
2
3
Pump speed
0: Off ; 1: On low speed ; 2: On high
speed (only visualization)
8
2
4
3-way valve position
0= sanitary; 1= heating ((only
visualization)
/
8
2
5
Sanitary flow meter (l/min)
(not active)
/
8
2
6
APS Status
0: open; 1: closed (only visualization)
/
8
2
8
Gas power (kW)
(only visualization)
/
8
3
BOILER TEMPERATURE
8
3
0
Temperature set on heating (°C)
(only visualization)
/
8
3
1
Temperature measured on
heating delivery (°C)
(only visualization)
/
8
3
2
Heating return measured
temperature (°C)
(only visualization)
/
8
3
3
Sanitary measured temperature
(°C)
(not active)
/
8
3
5
External temperature (°C)
(only visualization)
/
8
4
STORAGE AND SOLAR (if present)
8
4
2
Sanitary inlet temperature (°C)
(only with solar inlet sensor
connected)
(only visualization)