Pag. 59 di 69
0: Standard efficiency
1: High efficiency
Slow ignition as % of the
maximum heating power
0: disabled
1: 10 seconds
2: 90 seconds
3: 210 seconds
Conventional boiler
configuration
0: Monothermic open chamber
1: Monothermic open chamber VMC
2: Monothermic sealed chamber fan fix
speed
3: Monothermic sealed chamber fan
modulating speed
4 Bithermic open chamber
5 Bithermic sealed chamber
Depend on
the boiler
version
0: combi
1: Storage with NTC (tank)
2: only heating or storage with
thermostat
3: micro-storage
Depend on
the boiler
version
Absolute maximum heating
power
Maximum heating power
(heating absolute maximum
power percentage) (%)
Select of heating delay manage
0: manual (set with par. 2 36)
1: automatic
Heating delay (min), enabled by
par. 2 35= 0
Heating post-circulation (min)
Pump modulation on heating
0: speed 2 steady
1: speed 3 steady
2: modulating
ΔT for pump modulation (°C)
0 ÷ 60
(with Auto function working)
Heating water pressure
detection device
0: temperature probes only
1: pressure switch
2: pressure sensor
External temperature correction
(°C)
Sanitary comfort function
0: disabled
1: enabled for 30 minutes after a heating request
2: always enabled