40
settings - adjustment - problem identication menus
menu
sub-menu
Parameter
Description value
default setting
8 6 STATISTICS
8 6 0 Number of hours burner operating in heater mode (xxh)
8 6 1 Number of hours burner operating in hot water mode (xxh)
8 6 2 Number of ame separations
8 6 3 Number of ignition cycles
8 6 4 Number of lling cycles performed
8 6 5 Average length of heating request
8 7 E@SY HOTLINE NOT ACTIVE
8 7 0
8 7 1
8 8 ERROR LIST
8 8 0 10 last errors from E00 to E99
This parameter allows the last 10 boiler errors agged to be displayed, indicating the day, month and year.
When the parameter is accessed, the errors are displayed listed from E00 to E99.
For each error, the following sequence is displayed:
E00 - error number
108 - error code
A15 - A = day on which error E00 occurred
B09 - B = month during which error E00 occurred
C06 - C = year during which error E00 occurred
8 8 1 Error list reset
Reset
OK = yes
ESC = no
8 9 DATA - ASSISTANCE CENTRE
8 9 0 Enter the name of the assistance centre - it will be displayed if there is a fault which cannot be unlocked with the Reset button
"Assistance Centre Name" appears on the display,
press the MENU button and start entering the letters by turning the encoder. To
insert each letter, press the MODE button to conrm it and move on to the next letter.
8 9 1 Enter the number of the assistance centre - it will be displayed if there is a fault which cannot be unlocked with the Reset button
"Assistance Centre Number" appears on the display,
press the MENU button and start entering the digits by turning the encoder.
To insert each digit, press the MODE button to conrm it and move on to the next digit.