MAINTENANCE GUIDE
MAINTENANCE GUIDE: GENUS PREMIUM
3.13 SAFETY VALVE
SAFETY VALVE
Tools
Time
5 min
1
Drain boiler (see 3.3). Disconnect the
discharge pipe
Remove the first clip on the left and
pull the safety valve towards you
3.14 BY-PASS ASSEMBLY
BY-PASS ASSEMBLY
Tools
Time
5 min
1
Drain boiler (see 3.3). Remove the
second clip and pull the assembly
toward you
Push on the by-pass to disengage it
Page. 15 of 24
MAINTENANCE GUIDE: GENUS PREMIUM
3.15 TEMPERATURE SENSORS & OVERHEAT THERMOSTAT
TEMPERATURE SENSORS & OVERHEAT THERMOSTAT
Tools
Time
3.16 MANUAL AIR VENT
5 min
1
Unplug the electrical
connectors
Remove the clip and the
temperature sensor or
overheat thermostat together
IMPORTANT!!!!Do not use conducting paste for the contact sensors because it will alter the resistance value.
TEMPERATURE (°C) RESISTANCE (kOmh)
0 27
10 17
20 12
25 10
30 8
40 5
50 4
60 3
70 2
80 1
,
5
MANUAL AIR VENT
Tools
Time
5 min
1
Remove the clip and lift the manual air vent from the
exchanger
Page. 16 of 24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ariston CLAS HE Series and is the answer not in the manual?

Ariston CLAS HE Series Specifications

General IconGeneral
Efficiency RatingA
MountingWall-mounted
ERP RatingA
Warranty2 years
Fuel TypeNatural Gas

Related product manuals