SETTINGS - ADJUSTMENT - PROBLEM IDENTIFICATION MENUS
8 0 3
Boiler Life Time (h x 10)
8 0 4
Time of fan ON (h x 10)
8 0 5
Number of fan cycles (n x10)
8 0 6
Number of ame detection in CH (n x10)
8 1 7
Number of ame detection in DHW (n x10)
8 1
BOILER STATISTICS-2
8 1 0 Number of hours burner operating in heater mode (xxh/10)
8 1 1 Number of hours burner operating in hot water mode (xxh/10)
8 1 2 Number of ame separations (nr/10)
8 1 3 Number of ignition cycles (nr/10)
8 1 4 Average length of heating request (minutes)
8 2 BOILER
8 2 1 Fan Status 0 = OFF
1 = ON
8 2 2 Fan speed (x100) rpm
8 2 4 Diverter valve position 0 = D.H.W.
1 = Central Heating
8 2 7 Modulating Pump (%)
8 2 8 Gas Power (kW)
8 3 BOILER TEMPERTURE
8 3 1 Heating ow temperature (in °C)
8 3 2 Heating backow temperature (in °C)
8 4 SOLAR & STORAGE
8 4 2 Solar appliance water input temperature activated only with the solar kit
connected
8 5 SERVICE
8 5 0 Months to next maintenance from 0 to 60 (month) 24
If setted the boiler will display that is time to call the installer for maintenance
8 5 1 Enable Maintenance advice 0 = OFF
1 = ON
0
8 5 2 Maintenance Warning Reset Reset? OK= Yes Esc = No
to erase the advice for maintenance
8 5 3 2nd Heat Exchanger Clogging State 0 = DHW Exchanger OK
1 = Partially Clogged
2 = Very Clogged Please
Replace
8 5 4 PCB hardware version
8 5 5 PCB software version
8 6 ERROR LIST
8 6 0 10 last errors from ERROR 0 to ERROR 9
This parameter allows the last 10 boiler errors agged to be displayed, indicating the day, month and year.
When the parameter is accessed, the errors are displayed listed from ERROR 0 to ERROR 9.
For each error, the following sequence is displayed:
E00 - error number
108 - error code
8 6 1 Error list reset Reset
OK = yes
ESC = no
menu
sub-menu
Parameter
Description value
default setting

Table of Contents

Other manuals for Ariston CLAS SYSTEM One

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ariston CLAS SYSTEM One and is the answer not in the manual?

Ariston CLAS SYSTEM One Specifications

General IconGeneral
Fuel TypeNatural Gas / LPG
MountingWall-mounted
ErP Heating EfficiencyA
Modulation1:7
Heating Output24 kW
Warranty2 years

Related product manuals