MAINTENANCE GUIDE
5. ANNUAL MAINTENANCE
Plate heat exchanger
Maintenance Interval: As necessary
How: To measure specication of DHW performance.
By-pass & Safety valve
Maintenance Interval: Annually
How: Visual inspection / Clean as necessary
Central heating lter
Maintenance Interval: Annually
How: Visual inspection / Clean as necessary
Flow switch operation
Maintenance Interval: Annually
How: Visual inspection / Clean as necessary / Check ow rate
Expansion vessel
Maintenance Interval: Annually
How: Check air pressure is at 15 psi (System drained)
Ignition & detection electrode
Maintenance Interval: Annually
How: Visual inspection / Clean as necessary / Distance from the burner / Ionisation current
more than 1 μA
Burner
Maintenance Interval: Annually
How: Visual inspection / Clean as necessary
Fan
Maintenance Interval: Annually
How : Visual inspection / Clean as necessary

Table of Contents

Other manuals for Ariston CLAS SYSTEM One

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ariston CLAS SYSTEM One and is the answer not in the manual?

Ariston CLAS SYSTEM One Specifications

General IconGeneral
Fuel TypeNatural Gas / LPG
MountingWall-mounted
ErP Heating EfficiencyA
Modulation1:7
Heating Output24 kW
Warranty2 years

Related product manuals