Training manual CLAS X
Pag. 58 di 69
7 MENU AND SETTINGS
7.1 TECHNICIAN MENU
To enter in the in the technician menu push for 5 second the buttons and “OK”, and after set the access
code “234” and push the button “OK”.
7.2 COMPLETE MENU
7.2.1 Menù 0 : Network
7.2.2 Menù 2 : Boiler parameter
Menù
Sub Menù
Parameter
Function
Range
Default
setting
0
4
USER INTERFACE
0
4
0
Zone to be set by display
1 ÷ 3
1
0
4
1
Backlight time (min)
1 ÷ 10 ; 24h
24h
0
4
2
Thermoregulation button
deactivation
0: Off
1: On
1
Menù
Sub Menù
Parameter
Function
Range
Default
setting
2
0
GENERAL
2
0
0
DHW setpoint temperature
36 ÷ 60
/