Pag. 60 di 69
7.2.3 Menù 4 : Zone 1 parameters
Sanitary delay start
(anti water hammering) (dec)
Sanitary switch off logic
0: anti-scale (62 o 65°C).
1: set-point+4°C
Sanitary post-circulation and
post-ventilation
0: Post-ventilation: Tflow<75°C = no post-
ventilation; Tflow>75°C = 3 min (minimum
speed); Post-circulation: 30sec
1: Post-ventilation: 3min
Post-circulation: 3min
Heating start delay after sanitary
(min)
Antilegionella function (only for
boilers with external thank and
NTC sensor – par. 228 = 1)
Antilegionella frequency (h)
Antilegionella temperature (°C)
Boiler pump control
(set parameter 260 =1)
0: Off
1: On (timed 10 min)
Fan control
(set parameter 260 =1)
0: Off
1: On (timed 10 min)
Diverter valve control
(set parameter 260 =1)
0: Sanitary
1: Heating ( timed 10 min)
0: Off
1: On (select desired power)
Reset menu 2 factory setting
YES: press button “OK”
NO: press button “ESC”
Temperature setpoint zone 1
Select high or low temperature
for zone 1
(only with zone module)
0: low temperature
1: high temperature
Thermoregulation mode
selection
0: fixed delivery temperature
1: basic thermoregulation
2: only room probe
3: only outside probe
4: room probe + external probe
Select thermoregulation curve
0_2 ÷ 1_0 (par. 420=0)
1_0 ÷ 3_5 (par. 420=1)
(with Auto function enabled)
0_6 (par 420=0)
1_5 (par 420=1)
Select thermoregulation curve
parallel shifting
-7 ÷ 7 (par. 420=0)
-14 ÷ 14 (par. 420=1)
(with Auto function enabled )