maintenance guide
40
Tools
Time
10 min
1
Drain boiler (see 3.3). Remove the clip and the two screws Disconnect the pipe and then move the pump to the right
disengage
2
Remove the pump Remove the sensor (see 3.5)
3
Remove the AAV (see 3.4)