49
Tools
Time
15 min
1
Remove the combustion assembly
(see 4.3)
Remove the three screws to free the fan.
Twist the gas valve anti-clockwise to disengage it from
the fan
Legend:
1. Venturi
2. Gasket
3. Fan
Fan & Mixer venturi according to the model
Power Fan Venturi diameter
Model 24 EBM RG 128 45 W Ø 17 mm
Model 30 EBM RG 128 45 W Ø 21 mm
Model 38 EBM RG 128 45 W Ø 25 mm
Fan

Table of Contents

Other manuals for Ariston E-Combi 24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ariston E-Combi 24 and is the answer not in the manual?

Ariston E-Combi 24 Specifications

General IconGeneral
Output24 kW
Fuel TypeNatural Gas
MountingWall Mounted
Domestic Hot Water Output24 kW
TypeCombi Boiler
Efficiency RatingErP A