MAINTENANCE
Operational test
Afterhavingcarriedoutthemaintenanceoperations,ll
theapplianceandthewatercircuit.
- Beginoperatingtheboiler.
-Check the settings and make sure all the command,
adjustmentandmonitoringpartsareworkingcorrectly.
-Checkthesealandthatthesystemfortheexpulsionof
fumes/suctionofcomburentairisoperatingcorrectly.
Draining procedures
Thesystemmustbedrainedusingthefollowingprocedure:
-Removethebatteries,
-Shutoffthewatermainsinletvalve,
-Openthehotandcoldwatertaps.
WARNING
Beforehandling,emptyallcomponentswhichmaycontain
hotwater,performingbleedingwherenecessary.
Descale the components in accordance with the
instructionsprovided onthesafety dataleaet supplied
with the product used, make sure the room is well
ventilated,wearprotectiveclothing,avoidmixingdifferent
products, and protect the appliance and surrounding
objects.
Sealallopeningsusedtotakeagaspressurereadingor
tomakeanygasadjustments.
Makesurethatthenozzleiscompatiblewiththesupplied
gas.
Ifasmellofburningisdetectedorsmokeisseenleaking
fromtheappliance,orthereisasmellofgas,removethe
batteries,shutoffthegasvalve,openthewindowsand
callfortechnicalassistance.
Information for the user
Informtheuseronhowtooperatetheappliance.
Inparticular,providetheuserwiththeinstructionmanuals
and inform him/her that these must be stored with the
appliance.
Moreover,makesuretheuserisawareofthefollowing:
-Howtosetthetemperatureandadjustmentdevicesfor
usingtheappliancecorrectlyandinamorecost-efcient
way.
-Thesystem mustbe servicedregularlyincompliance
withlegislation.
-Thesettingsrelatingtothesupplyofcombustionairand
combustiongasmustnotinanyeventbemodied.
SYMBOLS USED ON THE DATA PLATE
Disposal and recycling the appliance.
Ourproductsaredesigned and manufacturedformostofthe
componentsofrecyclablematerials.
The appliance and its accessories have to be adequately
disposed and the various materials diff erentiated, where
possible.
Thepackagingusedforthetransportoftheappliancemustbe
disposalbytheinstaller/dealer.
ATTENTION!!
Recycling and disposal of the appliance and the
accessories must be made as required by regulations.
MIN MAX
10
Legend:
1. Brand
2. Manufacturer
3. IGWHmodel-Serialnumber
4. Commercialreference
5. Certicationnumber
6. Destinationcountry-Gascategory
7. Gas setting
8. Installation type
9. Maximumdomestichotwaterpressure
10. Deliveryrate
13. Inputratingnominalheating
14. Poweroutputheating
17. Gaseswhichmaybeused

Table of Contents