6.5.4 Removing the automatic air vent
1. Remove the U-clip “B1” (FIG. 6.58);
2
.
R
emove valve complete with float using a screwdriver
(FIG 6.59-FIG 6.60).
FIG. 6.58
FIG. 6.59
FIG. 6.60
B1
6.5.5 Removing the pump
1. Remove the electrical connetction “ B2” (FIG. 6.61);
2
.
R
elease the nut “B3” (F
IG.
6.62);
3. Remove the retainig clip “B4” from the side of the
pump housing (FI
G
. 6.63);
4. Remove the screw “B5” (FIG. 6.64);
5
.
R
emove the U-clip “B6” and remove the pressure
g
auge connection (F
IG.
6.65);
6. Remove the U-clip “B7” and remove the automatic air
vent (FI
G
. 6.66);
7. Remove the pump.
FI
G
. 6.61
B2
FIG. 6.62
B3
FIG.
6.63
B4