1X-F Series Operation Manual 7
Control/LED LED colour Description
General Test button
and LED
Yellow Tests a zone, sounders, fire protection (NEN
2535 only) or fire routing (when pressed with the
corresponding button).
A steady General Test LED and the
corresponding zone, sounders, or fire routing
Fault/Disable/Test LED indicates a test.
Numeric keypad
and Enter button
N/A Used to enter the operator user level password.
The Enter button is also used to disable or test
selected features (when pressed with the General
Disable or Test button).
For control panels in a network with repeater
functionality, the Enter button is used to show
control panel local events.
Reset button Yellow Resets the control panel and clears all current
system events (except expansion I/O board fault
communication).
A steady LED indicates that operator user level
is
active (see “User levelson page 13).
Panel Silence
button and LED
Yellow Silences the control panel buzzer and
acknowledges all current events.
A steady LED indicates that all current events
were acknowledged.
Sounder Start/Stop
button and LED
Red
The LED indicates what happens when the button
is pressed:
If the LED is on (flashing or steady), pressing the
button silences the fire sounders.
If the LED is off, pressing the button activates the
sounders (if the control panel status and
operating mode allow manual activation of
sounders).
The LED also indicates the status of the
sounders:
Steady indicates that sounders are active (or
will be activated shortly)
Flashing indicates that a delay is counting
(sounders are activated when the configured
delay elapses or when the delay is cancelled)
Off indicates that the sounders are off (or will
be deactivated shortly)
Notes
To prevent the immediate silencing of sounders
when an alarm is first reported, the Sounders
Start/Stop button may be temporarily prevented
when a configured fire sounder delay is counting
down.
Depending on the size of your installation, the
processing of commands to start or stop
sounders may take a few seconds to travel
through the system. For example, the LED may
be steady before the sounders are audible.

Other manuals for Aritech 1X-F Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Aritech 1X-F Series and is the answer not in the manual?

Aritech 1X-F Series Specifications

General IconGeneral
BrandAritech
Model1X-F Series
CategoryControl Panel
LanguageEnglish

Related product manuals