SPECIFICATIONS
Entrance Delay time 8 Seconds
Exit Delay time 30 seconds after no movement at
Sensor
Low Battery indicator Red LED flashes approx. once per
second and single beep every 20
seconds
Alarm sound reset time 1 minute
Intruder indication Green LED will light after resetting
of alarm to indicate a burglar was
detected
Alarm output approx. 110dB at 1 metre.
Wireless range of transmitters 20 metres approx.
Movement Activated Sensor Range 7 metres approx. and 90 degree
scan angle
TROUBLESHOOTING
Check that all house code switches in the Sensors and Control Panel
are set to the same code.
Doors and walls may reduce the range to less than 20 metres. Re-install
the Control Panel in a more central position to the Sensors.
Control Panel
Check batteries are new and installed with the correct polarity.
Check that the AC Adaptor is correctly fitted and switched on.
Check that the personal security code has been correctly programmed
in.
Movement Activated Sensor
Check that the battery has been installed correctly.
Check that the Movement Activated Sensor is not more than 20 metres
from the Control Panel. If the Movement Activated Sensor is mounted
near metal objects, it may have to be relocated.
Arm the Control Panel and walk in front of the Movement Activated
Sensor. The LED on the Movement Activated Sensor and the Control
Panel should light momentarily. After two minutes the unit will again be
ready to sense, reset alarm and test again.