EasyManua.ls Logo

Artesis eMCM - Appendices; 1. Appendix 1: MCM Error, alarm and warning conditions

Artesis eMCM
58 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
49
Appendices
1. Appendix 1: MCM Error, alarm and warning conditions
1.1 Error Conditions
Error Number
Error type
Description
0x010000
Memory
allocation error
The dynamic memory manager failed in a request to
allocate a block of memory
0x020000
General error
An unexpected or general error occurred
0x040000
Zero division
The algorithm attempted to perform a division by zero
0x080000
Flash Write
There was an error attempting to write to flash
0x100000
Illegal square
root
The algorithm attempted to form the square root of a
negative number
0x200000
Initialization
error
Initialization was not properly finished, or an error
occurred
0x400000
No data error
There is no data present
0x800000
Data acquisition
error
An error occurred during data acquisition causing
insufficient data to be acquired
0x01000000
Parameter error
An illegal value was calculated for an algorithm
parameter
0x02000000
Flash error
An attempt to read or write from the flash RAM gave
an error indicating a faulty flash. The device can only
be restarted by removing power and performing a
general reset
0x04000000
Cluster error
An illegal cluster value was detected.
0x08000000
Flash data error
Data stored in the flash RAM is corrupted and cannot
be used. This error is generated during both learn and
test modes following an attempt by the algorithm to
recover from another fault
0x10000000
Stability error
Clusters used by the algorithm are inherently unstable
0x20000000
Voltage range
error
An illegal voltage value was detected