REACH-INS SERVICE MANUAL/Rev. JUN. 2015
Page5
REACH IN REFRIGERATORS AND FREEZERS, ELECTRICAL SPECS
Models
HP
Voltage
Amp.
Max.
NEMA
Plug
Breaker
Size*
Wire gauge recommended for 2% voltage drop in supply
circuits **
40 ft ***
60 ft
80 ft
100 ft
120 ft
140 ft
ARR-17
1/4
115
220
5.8
3.2
5-15P
2P+TT
15 amp
10 amp
14 AWG
14 AWG
14 AWG
14 AWG
12 AWG
14 AWG
12 AWG
14 AWG
12 AWG
14 AWG
10 AWG
12 AWG
ARF-17
3/4
115
220
8.8
4.5
5-15P
2P+TT
15 amp
10 amp
14 AWG
14 AWG
14 AWG
14 AWG
12 AWG
14 AWG
12 AWG
14 AWG
12 AWG
14 AWG
10 AWG
12 AWG
ARR-17-1G
1/4
115
220
5.8
3.2
5-15P
2P+TT
15 amp
10 amp
14 AWG
14 AWG
14 AWG
14 AWG
12 AWG
14 AWG
12 AWG
14 AWG
12 AWG
14 AWG
10 AWG
12 AWG
ARR-23
1/4
115
220
5.6
3.1
5-15P
2P+TT
15 amp
10 amp
14 AWG
14 AWG
14 AWG
14 AWG
12 AWG
14 AWG
12 AWG
14 AWG
12 AWG
14 AWG
10 AWG
12 AWG
ARR-23-1G
1/4
115
220
6.0
3.4
5-15P
2P+TT
15 amp
10 amp
14 AWG
14 AWG
14 AWG
14 AWG
12 AWG
14 AWG
12 AWG
14 AWG
10 AWG
14 AWG
10 AWG
12 AWG
ARR-49
1/3
3/8
115
6.9
3.5
5-15P
2P+TT
15 amp
10 amp
14 AWG
14 AWG
12 AWG
14 AWG
12 AWG
14 AWG
10AWG
14 AWG
10 AWG
14 AWG
10 AWG
12 AWG
ARR-49-2G
1/3
3/8
115
220
6.9
3.9
5-15P
2P+TT
15 amp
10 amp
14 AWG
14 AWG
12 AWG
14 AWG
12 AWG
14 AWG
10 AWG
14 AWG
10 AWG
12 AWG
8 AWG
12 AWG
ARF-23
3/4
115
220
8.5
4.5
5-15P
2P+TT
15 amp
10 amp
14 AWG
14 AWG
12 AWG
14 AWG
10 AWG
14 AWG
10 AWG
12 AWG
8 AWG
12 AWG
8 AWG
12 AWG
ARF-23-1G
3/4
115
8.6
5-15P
15 amp
14 AWG
12 AWG
10 AWG
10 AWG
8 AWG
8 AWG
ARF-49
1
115
220
12.9
6.5
5-15P
2P+TT
20 amp
10 amp
12 AWG
14 AWG
10 AWG
12 AWG
8 AWG
12 AWG
8 AWG
12 AWG
8 AWG
12 AWG
6 AWG
12 AWG
Note:
*Breaker sizes are recommended to protect the equipment by overload; this breaker only must
be dedicated for the equipment.
** If the equipment is installed faraway of the circuit breaker, these are the wire gauge
recommend to connect the appliance; if the distance is higher that the chart values, please
contact an electrician.
***Distance in feet from the breaker or the power supply to the appliance.