4.3 Repair and
replacement
According to section 7.4.7.4 of IEC 61508-2 a useful lifetime based on experience, should be
assumed.
General field knowledge suggests that most solenoid valves have a useful life of 3 to 10 years, but may be
longer depending on the valve series and other factors.
It is
the
responsibility of the end user to establish a preventative maintenance process to replace all solenoids
before
the end of the useful
life.
4.4 ASCO
Notification
Any failures that are detected and that compromise functional safety should be reported to ASCO
Valve.
Please contact ASCO customer
service.
5 ASCO Solenoid Pilot Valves
Covered
Select ASCO valves from the following series have been evaluated per IEC 61508 parts 1 and 2 and
covered
under this
document:
8
314 Series - 3-Way Direct Acting Pilot
Valves
8
320 Series - 3-Way Direct Acting Pilot
Valves
8
316 Series - 3-Way Indirect Acting Pilot
Valves
5
51, 552, 553 Series - 3 and 4-Way Indirect Acting Pilot
Valves
8
317, 8320, 8321 Series - 3-Way Harsh Environment Pilot
Valves
327/8327 Series - 3-Way Direct Acting Pilot
Valves.
126 Series - 3-Way Direct Acting Pilot
Valves.
8317 Series – 3-Way Piloting Quick Exhaust valve
307 Series -
3-Way Direct Acting Pilot
Valves
364 Series – 3-Way Spool Valves
362/562 Series – 3-Way and 4-Way Spool Valves
381 Series – 3-Way Poppet Valves
8800 Series – 3-Way High Flow Quick Exhaust Valves
6 Status of the
document
6.1
Releases
Revision: K
ECN Number: 288862
Release status: V9629 Initial Release on
02/18/11