TD 92989EN
15 October 2014 / Ver. B
Installation Guide
IP-DECT Base Station & IP-DECT Gateway
35
Appendix A. RFP Power Consumption
The tables below show power consumption for a base station connected to and powered
from the IPBL.
The maximum cable length for base stations connected to the IPBL must not
exceed 1500
meters.
A.1 KRCNB 201
Table 1 Power consumption (watts) of base stations and cabling when powered from the IPBL.
Cable
length
(metres)
0.4 mm
wire size
()
0.4 mm
wire size
()
0.5 mm
wire size
()
0.5 mm
wire size
()
0.6 mm
wire size
()
0.6 mm
wire size
()
Without
EPP
With
EPP
Without
EPP
With
EPP
Without
EPP
With
EPP
0 7.5 7.5 7.5 7.5 7.5 7.5
100 7.9 7.8 7.8 7.7 7.7 7.6
200 8.3 8.0 8.0 7.8 7.8 7.7
300 8.9 8.3 8.3 8.0 8.0 7.8
400 9.8 8.7 8.7 8.2 8.2 7.9
500 11.3 9.2 9.2 8.5 8.4 8.0
600 - 9.8 9.8 8.7 8.6 8.2
700 - 10.7 10.7 9.0 8.8 8.3
800 - 12.3 12.3 9.4 9.1 8.4
900 - - - 9.8 9.5 8.6
1000 - - - 10.3 9.9 8.8
1100 - - - 11.1 10.4 8.9
1200 - - - 12.3 11.1 9.1
1300 - - - - 12.1 9.3
1400 - - - - - 9.6
1500 - - - - - 9.9