INSTALLATION GUIDE
tCM - Migration ControllerInstallation Guide (NUMIPCE-H) Mounting
8. Prepare the NIRC4 board::
Legend:
(1) NIVP speech board
(2) LAN connector
(3) 4x Roombus
If speech is used: connect the NIVP board (see item 1)
Connect the LAN cable (see item 2)
Warning: Do not use PoE
Screw the four provided 6–pin connectors tightly on the 4 roombuses (item 3) of the NIRC4. The
connectors are mounted on pin2–7, pin 1 and pin 8 are left vacant.
9. Mount the NIRC4 onto the NUMIPCE-H board.
The four 6–pin connectors must line-up with the four 6–pin headers on the NUMIPCE-H board. Press
firmly and ensure that the NIRC4 board is level.