39
Engineering & Physical Data ACK-E-2009
General Data - Cooling Only (R22)
MODEL
INDOOR UNIT ACK 40E ACK 40E
OUTDOOR UNIT ALC 35C ALC 40C
NOMINAL CAPACITY - 1Ø <3Ø>
Btu/h 35000 39000 <40000>
W 10258 11430 <11723>
NOMINAL TOTAL INPUT POWER - 1Ø <3Ø>
W 3010 3450 <3260>
NOMINAL RUNNING CURRENT - 1Ø <3Ø> A 14.4 16.7 <5.8>
POWER SOURCE - 1Ø <3Ø>
V/Ph/Hz 220 - 240 / 1 / 50
220 - 240 / 1 / 50
<380 - 415 / 3 / 50>
EER - 1Ø <3Ø> W/W 3.41 3.31 / <3.59>
REFRIGERANT TYPE R22 R22
REFRIGERANT CONTROL (EXPANSION DEVICE) INDOOR CAP. TUBE INDOOR CAP. TUBE
INDOOR UNIT
CONTROL
AIR DISCHARGE
4 WAY AUTOMATIC LOUVER
(UP & DOWN)
4 WAY AUTOMATIC LOUVER
(UP & DOWN)
OPERATION
WIRELESS OR WIRED MICRO-
COMPUTER REMOTE CONTROL
WIRELESS OR WIRED MICRO-
COMPUTER REMOTE CONTROL
AIR FLOW
HIGH l/s / CFM 490 / 1030 490 / 1030
MEDIUM l/s / CFM 410 / 860 410 / 860
LOW l/s / CFM 350 / 740 350 / 740
EXTERNAL STATIC PRESSURE (H/M/L) Pa / in.wg. 00
SOUND PRESSURE LEVEL (H/M/L) dBA 44 / 41 / 38 44 / 41 / 38
UNIT DIMENSION
( ) - WITH PANEL
HEIGHT mm/in 300 (375) / 11.81 (14.76) 300 (375) / 11.81 (14.76)
WIDTH mm/in 820 (990) / 32.3 (38.98) 820 (990) / 32.3 (38.98)
DEPTH mm/in 820 (990) / 32.3 (38.98) 820 (990) / 32.3 (38.98)
PACKING DIMENSION
( ) - PANEL
HEIGHT mm/in 335 (110) / 13.19 (4.3) 335 (110) / 13.19 (4.3)
WIDTH mm/in 916 (1030) / 36.1 (40.6) 916 (1030) / 36.1 (40.6)
DEPTH mm/in 916 (1030) / 36.1 (40.6) 916 (1030) / 36.1 (40.6)
UNIT WEIGHT (UNIT + PANEL) kg/lb 42+6 / 92.6+13.2 42+6 / 92.6+13.2
CONDENSATE DRAIN SIZE mm/in 19.1 / 0.75 19.1 / 0.75
OUTDOOR UNIT
AIR FLOW l/s / CFM 1605 / 3400 1605 / 3400
SOUND PRESSURE LEVEL dBA 58 58
UNIT DIMENSION
HEIGHT mm/in 850 / 33.5 850 / 33.5
WIDTH mm/in 1030 / 40.6 1030 / 40.6
DEPTH mm/in 400 / 15.8 400 / 15.8
PACKING DIMENSION
HEIGHT
mm/in 1000 / 39.4 1000 / 39.4
WIDTH mm/in 1200 / 47.2 1200 / 47.2
DEPTH mm/in 560 / 22.1 560 / 22.1
UNIT WEIGHT kg/lb 95 / 209 100 / 221
PIPE CONNECTION
TYPE FLARE VALVE FLARE VALVE
SIZE
LIQUID mm/in 9.5 / 3/8 9.5 / 3/8
GAS mm/in 19.1 / 3/4 19.1 / 3/4
REFRIGERANT CHARGE kg/lb 2.7 / 5.95 2.95 / 6.50
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.5m BELOW FASCIA.
07-General data_A.indd 3907-General data_A.indd 39 4/6/2009 11:13:07 AM4/6/2009 11:13:07 AM