ACK-E-2009 Engineering & Physical Data
General Data - Cooling Only (R410A)
MODEL
INDOOR UNIT A5CK 28E
OUTDOOR UNIT A5LC 28C
NOMINAL CAPACITY
Btu/h 27000
W 7913
NOMINAL TOTAL INPUT POWER W 2790
NOMINAL RUNNING CURRENT A 13.1
POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50
EER W/W 2.84
REFRIGERANT TYPE R410A
REFRIGERANT CONTROL (EXPANSION DEVICE) OUTDOOR CAP. TUBE
INDOOR UNIT
CONTROL
AIR DISCHARGE
4 WAY AUTOMATIC LOUVER
(UP & DOWN)
OPERATION
WIRELESS OR WIRED MICRO-
COMPUTER REMOTE CONTROL
AIR FLOW
HIGH l/s / CFM 410 / 860
MEDIUM l/s / CFM 340 / 725
LOW l/s / CFM 290 / 620
EXTERNAL STATIC PRESSURE (H/M/L) Pa (in.wg.) 0
SOUND PRESSURE LEVEL (H/M/L) dBA 41 / 38 / 35
UNIT DIMENSION
( ) - WITH PANEL
HEIGHT mm/in 265 (340) / 10.43 (13.39)
WIDTH mm/in 820 (990) / 32.3 (38.98)
DEPTH mm/in 820 (990) / 32.3 (38.98)
PACKING DIMENSION
( ) - PANEL
HEIGHT mm/in 300 (110) / 11.8 (4.33)
WIDTH mm/in 916 (1030) / 36.1 (40.6)
DEPTH mm/in 916 (1030) / 36.1 (40.6)
WEIGHT (UNIT + PANEL) kg/lb 29+6 / 63.9+13.2
CONDENSATE DRAIN SIZE mm/in 19.1 / 0.75
OUTDOOR UNIT
AIR FLOW l/s / CFM 684 / 1450
SOUND PRESSURE LEVEL dBA 54
UNIT DIMENSION
HEIGHT mm/in 756 / 29.8
WIDTH mm/in 855 / 33.7
DEPTH mm/in 328 / 12.9
PACKING DIMENSION
HEIGHT
mm/in 810 / 31.9
WIDTH mm/in 990 / 39.0
DEPTH mm/in 415 / 16.3
UNIT WEIGHT kg/lb 68 / 150
PIPE CONNECTION
TYPE FLARE VALVE
SIZE
LIQUID mm/in 9.5 / 3/8
GAS mm/in 15.9 / 5/8
REFRIGERANT CHARGE kg/lb 2.125 / 4.68
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL SPECIFICATIONS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.5m BELOW FASCIA.