DW 953, 954, 955, 95FI
SETTING OF PUMPING-OUT TIME
The pumping-out time can be changed depending on bad pumping-out
conditions.
Press S3 five times.
Press S3 to get an outlet time of 20 seconds or
press S4 " 25 seconds or
press S5 " 35 seconds or
press S6 " 45 seconds or
press S7 " 85 seconds
PROLONGED START FUNCTION
The start function can be re-programmed so that the button must be pres-
sed in for 3 seconds to start the programs.
Press S4 five times.
Press S5 to get a prolonged start function or
press S4 to get a normal start function.
SETTING OF INLET TIME
There is a possibility to re-programme the inlet time on level controlled and
time controlled inlets.
Press S5 five times.
Press S3 to get a normal inlet time or
press S4 to get a prolonged time of 25% or
press S5 " 50% or
press S6 " 100% or
press S7 " 150% or
press S8 " 200% .
EXTRA RINSE (Not DW 953)==
An extra rinse can be added in programs Intensive, Strong, Normal
and Lightwash.
Press S2 five times
Press S5 to get an extra rise or
press S4 to get a normal number of rinses.