Troubleshooting
The machine will not start
Check
that the door is properly closed.
that the main power switch is on.
that the Delayed Start option has not been
selected. To cancel Delayed Start, press the
Stop button for three seconds.
that the plug is connected.
that the main fuses have not blown.
that the overheating cut-out has not been
triggered.
The machine loses all power during a
programme
The overheating cut-out shuts o the tumble
dryer if the temperature is too high, e.g. because
dust is clogging the lint lter.
Clean the lint lter.
Check also that the condensed water
container is not full and, if necessary, clean
the condenser.
See the Care and cleaning chapter.
Wait until the machine has cooled then try
starting it. If it still does not start: Call the
service division.
Drying takes too long
Check that the lint lter is not blocked. See
the Care and cleaning chapter.
Empty the condensed water container and
check that the condenser is not blocked. See
the Care and cleaning chapter.
Overly long drying times may also be due to
the tumble dryer being located in a conned
area or in a room that is too small, causing
the air to become too hot.
Make sure that the tumble dryer has access
to more cold air, open doors and/or windows,
for example.
Error messages
If Over Flow appears on the display, the
condensed water container is full. Empty the
container and restart the machine.
Read Drying takes too long in this chapter if
Max program time appears on the display.
If Clean Lint Filter appears on the display,
clean the lint lter.
If Clean condenser appears on the display,
clean the condenser. See the Care and
cleaning chapter.
Call the service division if Thermistor fault
appears on the display.
Press the Stop button to close any error
messages.

Related product manuals