USER MANUAL
ACTIVE AIR BARI 10
ALTERNATING MATTRESS REPLACEMENT
PTM639500 - Single
PTM639510 - King Single
PTM639520 - Super King Single

Questions and Answers

  • M
    Michael PorterAug 2, 2025
    What to do if the Aspire ACTIVE AIR BARI 10 Medical Equipment pump is not working?
    • E
      Erica BestAug 2, 2025
      If the Aspire Medical Equipment pump isn't working, first ensure it's properly connected to a power source and that the power switch is in the ON position. If the issue continues, it's best to contact your Aspire dealer for further assistance.
  • R
    Rachel LarsonAug 6, 2025
    What to do if the alarm is sounding on my Aspire ACTIVE AIR BARI 10 Medical Equipment?
    • E
      Eric GlennAug 6, 2025
      If the Aspire Medical Equipment alarm is sounding, press the mute button to allow the system to verify. If the alarm continues after muting, contact your Aspire dealer.
  • B
    Brandon Miller PhDAug 10, 2025
    What to do if low pressure LED light is flashing on Aspire Medical Equipment?
    • R
      Rodney LongAug 10, 2025
      If the low pressure LED light is flashing or the alarm is going off on your Aspire Medical Equipment, make sure the CPR valve is in the CLOSED position, the air hoses/tubes are tightly secured, and all coupling connections along the mattress are secure. If the problem continues, contact your Aspire dealer.
  • E
    erin54Aug 15, 2025
    What to do if Aspire ACTIVE AIR BARI 10 Medical Equipment has a power failure?
    • B
      Breanna LittleAug 15, 2025
      If your Aspire Medical Equipment pump experiences a power failure, check that the pump is connected to the mains power supply and that the power switch is in the ON position. If the problem persists, contact your Aspire dealer.
  • J
    joseph64Aug 18, 2025
    What to do if Aspire Medical Equipment is bottoming out but no alarm?
    • J
      Jimmy WebbAug 19, 2025
      If the Aspire Medical Equipment mattress is bottoming out but there's no alarm, check that the pressure setting is correct for the patient. Adjust the comfort dial according to the patient weight range. Also, refer to the troubleshooting steps for a flashing low-pressure light or alarm. If the problem continues, contact your Aspire dealer.
  • S
    Shelly RogersAug 23, 2025
    Why is my Aspire ACTIVE AIR BARI 10 pump on but the mattress will not alternate?
    • A
      Adam BradyAug 23, 2025
      If the Aspire Medical Equipment pump is on but the mattress will not alternate, make sure that the mattress is inflated. Also, check that the ALTERNATING mode is turned ON. If the SERVICE REQUIRED LED is illuminated, contact your Aspire dealer.
  • D
    Danielle SweeneyAug 28, 2025
    How to fix a noisy Aspire ACTIVE AIR BARI 10 pump?
    • C
      Christopher MeltonAug 28, 2025
      If the Aspire Medical Equipment pump is noisy, ensure it is correctly mounted and flat against the FOOT end of the bed. If the noise persists, contact your Aspire dealer.

Summary

1. Introduction to Aspire Air Mattress

Clinical Use and Patient Benefits

Appropriate for Bariatric patient care, aiming to reduce pressure injuries and enhance comfort.

Product Description and Features

Key Features of the Active Air BARI 10

Highlights of the mattress system including weight range, cycle types, pump features, and material specifications.

2. Safety Precautions

General Operational Safety

General safety guidelines for operating the mattress replacement and pump, including electrical safety and patient considerations.

3. Product Safeguards

Electrical Safety Measures

Precautions related to electrical safety, including avoiding water and damaged cords.

Safe Use for Patients and Carers

Guidelines for safe operation, supervision, and maintenance to prevent harm.

5. Assembly and Setup Guide

Mattress Placement and Securing

Instructions for correctly positioning and securing the mattress replacement onto the bed platform.

5. Assembly and Setup Guide

CPR Valve and Pump Positioning

Instructions on setting the CPR valve and placing the pump unit at the foot end of the bed.

5. Assembly and Setup Guide

Connecting Air Hose and Sensor Cable

Procedure for connecting the air hose and sensor cable to the pump unit.

5. Assembly and Setup Guide

Power Connection and Initial Mode Setup

Steps for connecting power to the pump and selecting the initial patient mode.

6. Operation of the Mattress System

Control Panel and Function Overview

Overview of the digital pump's control panel and its functions.

6. Operation of the Mattress System

Powering On and Using Function Lock

Steps to turn on the pump and how to enable/disable the function lock feature.

6. Operation of the Mattress System

Auto Firm and Pressure Mode Selection

How to use Auto Firm and select pressure modes like Static, Alternating, and Pulsate.

6. Operation of the Mattress System

Alternating and Pulsate Mode Functions

Details on 2-in-1, 4-in-1 alternating modes and the Pulsate mode for breathing exercises.

6. Operation of the Mattress System

Pressure Adjustment and Patient Weight Guide

How to adjust pressure and use the patient weight guide for optimal settings.

6. Operation of the Mattress System

Auto Protect and Bariatric Mode Features

Functionality of Auto Protect and activation of Bariatric Mode for heavier patients.

6. Operation of the Mattress System

Turning Modes and Alarm Muting

Instructions for turning modes and how to mute pump alarms.

6. Operation of the Mattress System

Operational Indicators and Alarm Explanations

Explanation of Low Pressure, Power Failure, and Service Required indicators and alarms.

General Operation: CPR Function

CPR Quick Deflation Procedure

Procedure for quick deflation of the mattress in case of a CPR emergency.

7. Product Specifications

Pump and Mattress Specifications Details

Technical specifications for the pump unit and mattress replacements across different sizes.

8. Cleaning Instructions

Pump and Mattress Cover Cleaning

Instructions for cleaning the pump unit and the mattress cover, including washing and drying.

9. Maintenance and Storage

Maintenance and Filter Replacement Guide

Routine checks, fuse, and air filter replacement procedures for the pump.

Mattress Storage Instructions

Steps for safely releasing air and storing the mattress replacement.

10. Troubleshooting Common Issues

Connection and Operation Problems

Troubleshooting steps for pump connection, operation, and alternating problems.

Alarm, Performance, and Warning Codes

Addressing alarms, noisy pump, bottoming out, and interpreting warning codes.

11. Warranty and Service Information

Warranty Claims and Consumer Rights

Information on warranty coverage for defects and consumer rights.

Service and Contact Information

Details for servicing, preventative maintenance, and general inquiries about Aidacare products.

Overview

The Aspire Lifecomfort Active Air BARI 10 Alternating Mattress Replacement is an electrically operated mattress system designed for the prevention and relief of pressure injuries, particularly for bariatric adult patients at high to very high risk. It aims to optimize patient comfort and enhance healing through alternating therapy. This product is suitable for various environments, including home care, aged care, and hospitals.

Function Description:

The system comprises a digital mattress pump and a mattress replacement. The pump features digital pressure adjustment, multiple mode selections, patient turning capabilities, and audiovisual alarms. The mattress itself consists of 20 alternating air cells and is covered with a multi-stretch, vapor-permeable fabric. It operates on the principle of alternating air pressure to redistribute pressure, reduce friction and shear, and optimize skin microclimate.

Important Technical Specifications:

Pump:

  • Dimensions: 400mm (W) x 175mm (D) x 275mm (H)
  • Weight: 6.5kg
  • Alternation Cycle Times: 10, 15, 20 minutes
  • Turning Cycle Times: 10-95 minutes
  • Pulsate Cycle Times: 10, 15, 20 minutes
  • Auto Firm Time: 20 minutes
  • Pump Output Pressure Range: 10-46mmHg (±5)
  • Power: AC230 V 50Hz
  • Current: 3.0 AMPS
  • Fuse Rating: T5A 250VAC
  • Frequency: 50 Hz (230V)
  • Classification: Class I, Type BF
  • Operation Environment: 5°C - 35°C, 15%RH - 93%RH (no condensation)
  • Storage Environment: -25°C - 70°C, 93%RH (no condensation)
  • Environment Pressure: 70 kPa-101.3kPa
  • Environment Horizontal Pressure: <3000mm
  • Water and Dust Protection Classification: IP21

Mattress Replacement:

  • Single Dimensions: 2000mm (L) x 900mm (W) x 270mm (H)
  • King Single Dimensions: 2000mm (L) x 1050mm (W) x 270mm (H)
  • Super King Single Dimensions: 2000mm (L) x 1230mm (W) x 270mm (H)
  • Single Weight: 14kg
  • King Single Weight: 15kg
  • Super King Single Weight: 16kg
  • Cell Material: TPU
  • No. of Air Cells: 20
  • Cover Material: Multi-stretch PU coated fabric with high MVTR
  • Bottom Material: Polyester-PU
  • Max Weight: 450kg
  • Patient Weight Range: 30-450kg

Usage Features:

  • Patient Weight Range: Supports patients from 30kg to 450kg, ensuring effective pressure redistribution within this range.
  • Alternating Air Cycles: Offers 1-in-2 and 1-in-4 alternating air cycles for acute level therapy, maximizing pressure redistribution and wound management.
  • Turning Cycle: Enables safe patient transfer and lateral movement, improving manual handling and wound therapy outcomes. Cycle times range from 10 to 95 minutes.
  • Quick Inflation Blower Pump: A high-powered pump ensures rapid inflation and supports loads up to 450kg.
  • AutoLock: The control panel automatically locks after 2 minutes of inactivity to prevent accidental changes.
  • AutoProtect (Fowler Function): Automatically increases air pressure in the pelvic region when the bed backrest is raised (10mmHg at 25°+, 15mmHg at 45°+) to prevent bottoming out. Can also be manually activated.
  • 24 Hour Transport: In case of power failure, the mattress remains inflated for up to 24 hours.
  • Easy-to-read LCD: Provides clear information on cycle time selections, operating modes, and fault conditions.
  • Multi-stretch, Vapour Permeable Cover: Easy to clean, breathable, and reduces friction and shear.
  • Welded Seams & Zip Protection: Prevents fluid and bacterial ingress, aiding infection control.
  • Rapid Release CPR Valve: Allows quick deflation for cardio-pulmonary resuscitation in emergencies.
  • Audible & Visual Alarms: Activate immediately upon problem detection, enhancing safety.
  • Variable Speed Pump: Automatically adjusts speed to the minimum required for effective pressure care, reducing noise and vibration for improved patient sleep quality.
  • Variable Cycle Times: Offers 10, 15, or 20-minute cycles for alternating and pulsate modes, and 10 to 95-minute cycles for turning mode, catering to diverse patient needs and comfort.
  • Simple Cell Connections: O-ring connections facilitate hassle-free and tool-free maintenance.
  • Static Mode: Reduces mattress pressure to 70% of the selected comfort level, stopping alternation.
  • Auto Firm: Inflates the mattress to maximum pressure for patient ingress, egress, or meal times. Automatically reverts to the previous mode after 20 minutes.
  • Pulsate Mode: Intermittently fully inflates the mattress to support breathing exercises, then reduces to 70% inflation pressure for comfort.
  • Bariatric Mode: Activated by pressing 'FIRM' & 'BARIATRIC' buttons, designed for patients over 160kg requiring higher pressure care.
  • Mute Function: Silences alarms temporarily; reactivates if the issue is not resolved, ensuring safety.

Maintenance Features:

  • Hassle Free Pump Maintenance: Modular pump design allows for quick servicing and minimal downtime.
  • Power Cord Protection: L-shaped connection with a protector function reduces the risk of the power cord becoming loose or damaged.
  • Cable Management: Retainer loops help manage cables, preventing trip hazards and damage.
  • Cell Retention Band: Prevents inadvertent movement or separation of cells, reducing friction and shear.
  • General Checks: Regularly inspect the mains power cable, plug, mattress cover for wear/damage, and air hoses for kinks/breakages.
  • Fuse Replacement: Disconnect power, remove the side casing cover, replace the fuse with an Aspire Dealer-supplied fuse of correct rating/specification, and re-secure the cover.
  • Air Filter Replacement: Remove the rear casing cover, replace the old filter with an Aspire Dealer-supplied filter of correct rating/specification, and re-secure the cover. Filters can be cleaned with mild detergent and warm water if not requiring replacement, ensuring it is dry before reinstallation.
  • Cleaning:
    • Pump: Wipe with a damp cloth pre-soaked in mild detergent. Keep free of dust. DO NOT immerse or soak.
    • Mattress Cover: For small spills, wipe with a damp cloth pre-soaked in mild detergent or disinfectant wipe. For large spills, remove the top cover by unzipping all 4 sides. Prewash and main wash at up to 95°C for 15 minutes. Dry on a line/air dryer or tumble dry on low heat for up to 90 minutes. Reattach by zipping all 4 sides. DO NOT use phenol-based products. Ensure the mattress is completely dried before use. DO NOT dry in direct sunlight to prevent text wear.
  • Storage: Release all air from the mattress and bolsters using the CPR valve and disconnecting hoses. Lay the mattress flat, roll from the head end towards the foot end, tighten straps into clamps to prevent unrolling, and secure with a packing strap.

The product comes with a 1-year warranty for the mattress replacement and a 2-year warranty for the pump. Proof of purchase is required for warranty commencement. Aidacare provides customer service and support for all warranty and servicing needs.

Aspire ACTIVE AIR BARI 10 Series Specifications

General IconGeneral
BrandAspire
ModelACTIVE AIR BARI 10 Series
CategoryMedical Equipment
LanguageEnglish