EasyManua.ls Logo

Assa Abloy 1584 Series - SPECIALIZED MOUNTING AND DIMENSIONS; Fig. 4.2 TYPICAL MOUNTING FOR PULL APPLICATION WITH Z BRACKET; Fig. 5 FACE MOUNT MAGNET DIMENSIONS AND ASSEMBLY; DOUBLE DOOR MOUNTING

Assa Abloy 1584 Series
4 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3
Copyright © 2009, Sargent Manufacturing Company, an ASSA ABLOY Group
company. All rights reserved. Reproduction in whole or in part without the
express written permission of Sargent Manufacturing Company is prohibited.
A7361A
STOP
(2) #14 HEX
S
HEET METAL
SCREW
Z BRACKET
DOOR
MAGNALOCK
DOOR
HEADER
M
OUNTING 
SCREWS
W
ASHERS (2)
USE 1" MOUNTING
SCREW SUPPLIED
W
ITH Z BRACKET
ARMATURE
SEX BOLT
(
DRILL 1/2" 
13 mm HOLE)
CAP SCREW
5
/16"-18
(8mm-1.25mm)
DRESS COVER SLIDES ON 
LAST WITH OPEN SIDE UP
AND IS ATTACHED WITH 
SUPPLIED DOUBLE STICK TAPE
T
-NUT REQUIRES
3/8" (10 mm) DIA HOLE
I
N BRACKET AND
ACCEPTS STRIKE
MOUNTING SCREW.
R
OLL PIN PLASTIC
BUSHINGS REQUIRE 1/2"
(
13 mm) HOLES AND MUST
BE SHORTENED TO WORK
I
N Z BRACKET.
Fig. 5 FACE MOUNT MAGNET DIMENSIONS
AND ASSEMBLY
A
B
C
D
E
F
G
G
GOLD WASHER
BLIND NUT
CABLE EXIT
TAMPER CAP
(US VERSION)
1/4-20 X 2 1/2"
(METRIC VERSION)
6mm-1mm X 60mm
DOUBLE DOOR MOUNTING
It is very common to use electromagnetic locks on double doors as most electromechanical locks cannot be utilized. In some cases
one of the door leaves is inactive so that only one leaf is used and this is secured by a single electromagnetic lock. If both leaves
are to be active, 2 electromagnetic locks can be used. For the most attractive installation, they should be butted together but if
obstructions exist in the header that interferes with mounting, the magnets can be separated and covered with an 18" dress cover
for push applications.
Fig. 4.2 TYPICAL MOUNTING FOR A PULL
APPLICATION WITH Z BRACKET
In cases where the electromagnetic lock must be
mounted on the inswinging side of the door to
p
rotect it from physical assault, the magnet body is
mounted flush on the wall above the door frame and
a
“Z” bracket is affixed to the door which positions
the armature in front of the magnet (part #15-2114
or Z bracket). SARGENT’s 1586 and 1587
electromagnetic locks have mounting holes through
the face of the magnet and wire that exits to the rear
for pull mounting applications. Figure 5 shows this
configuration. Note that when the roll pin bushings
are used, they protrude through the Z bracket and
interfere with the Z bracket cover. Roll pin bushings
m
ust be used to provide insulation. They should be
cut with a hacksaw to function in the bracket.
ABCDEFG
8.0 1.75 2.9 .5 1.48 .5 .45
MAGNET DIMENSIONS (INCHES)
ABCDEFG
203.2 44.45 73.66 12.7 37.59 12.7 11.43