ASSA ABLOY motor locks installation guide
10
The most important advice is to follow the installation
instructions and not to deviate from them without first
consulting us at ASSA ABLOY.
The guarantee is invalidated if:
• The product is incorrectly installed.
• The product is opened (seal is broken) or if cables/
connectors are cut off.
• The product is installed with accessories or parts
that are not recommended by ASSA ABLOY.
Maintenance:
• Make sure that the fitted cylinders, thumb turns and
handles work satisfactorily.
• Lubricate and/or adjust as needed with
ASSA ABLOY’s recommended lock grease.
• Electrical parts do not require any maintenance.
• Lubricate the bolt and latch in the lock case at least
twice a year. Locks that are used very frequently
require more frequent maintenance.
• It is also important to maintain and, if necessary,
adjust the door closer and hinges to ensure the
door closes properly. Correct maintenance of doors
is essential for effective operation of locks.
Important information and maintenance
Lock case Brief description CE cert. SSF 3522 class 3 SS-EN 14846
813C-50 Manual latch bolt CPR 21-524 0.97
815C-50 Manual latch bolt CPR 21-524 1.06
820C-50 Manual hook bolt and manual latch bolt CPR 21-524 21-640 640
825C-50 Manual hook bolt, single hand opening, cylinder override CPR 21-524 21-640 640
835C-50 Auto hook bolt, single hand opening, cylinder override CPR 21-524 21-640 640
835C 3 X 8 F 0 L 5 1 3
820C, 825C 3 X 8 F 0 L 3 1 3
815C, 813C 3 X 8 F 0 L 1 1 3 SBSC 21-563
Certification
Important information
• Do not use lubricants that contain graphite or
solvents; only use lock lubricant from ASSA ABLOY.
• The safety features of this product are vital for its
compliance with EN 14846 and SSF3522-1093.
• No modification or alteration of any kind other than
described in these instructions is permitted.
• The lock case is intended for installation in a single
or double door **, made from wood, aluminium or
steel. The door must not weigh more than 200 kg.
• Depending on the type of door, different mounting
screws may be needed.
* The fire test was performed on a glazed uninsulated door constructed
from steel profiles. The lock tested was an 835C-50 model.
** If the lock is used in a double door, a door coordinator must be fitted.