Attention Installer:
Please read these instructions carefully to prevent missing important steps.
Improper installations may result in damage to the lock and void the factory warranty.
The accuracy of the door preparation is critical for proper functioning and security of this lock.
Misalignment can cause premature wear and a lessening of security.
Installation Instructions
SN
Series
SN200 Wiegand
SN210 OSDP
ED5000 Series
Exit Device
With MELR
For Technical Assistance call Corbin Russwin at 1-800-810-WIRE (9473)

Questions and Answers

  • D
    Danielle DiazAug 12, 2025
    How to troubleshoot Assa Abloy Corbin Russwin SN units with Door Position Switch made by other manufacturers?
    • S
      sanfordkimberlyAug 12, 2025
      To troubleshoot Assa Abloy Door Opening System units that incorporate a Door Position Switch (DPS) from other manufacturers: * Ensure the DPS is wired correctly (electrically closed when the door is closed) into the wire harness. * Verify the DPS is functioning properly by using a meter to check continuity when the door is opened and closed.
  • C
    Colton RodriguezAug 19, 2025
    What to do if Assa Abloy Corbin Russwin SN alarms continuously when power is applied?
    • J
      Jeffery MccarthyAug 19, 2025
      If your Assa Abloy Door Opening System alarms continuously when power is applied, check the trigger mechanism wire harness on the circuit board and all other connections. Also, check the pushpad activating switch in the device.
  • W
    woodkristineAug 27, 2025
    What to do if Assa Abloy Door Opening System allows mechanical latchbolt retraction with power applied and LED shows armed?
    • M
      Matthew SolomonAug 27, 2025
      If the Assa Abloy Door Opening System allows mechanical latchbolt retraction even when power is applied and the LED indicates it's armed, verify that the power supply provides the correct regulated 24VDC. Also, ensure the power supply has the correct amperage, rated equal to or greater than the device's requirement, with a minimum of 500mA.
  • B
    Bryan LewisSep 4, 2025
    What to do if Assa Abloy Corbin Russwin SN Door Opening System will not arm (no red LED)?
    • S
      Samantha TuckerSep 4, 2025
      If your Assa Abloy Door Opening System doesn't arm (no red LED), you can try the following: * Check all connections on the circuit board and wire harness. * Confirm that there is 24VDC power at the power inputs (-black) and (+red), and verify the polarity. * Inspect the wire transfer for any bad connections or broken wires. * Check the power output at the power supply to ensure it is a regulated 24VDC.

Assa Abloy Corbin Russwin SN Series Specifications

General IconGeneral
Product TypeMortise Lock
SeriesSN Series
BrandCorbin Russwin
GradeANSI/BHMA Grade 1
Door Thickness1-3/4 inches
Backset2-3/4 inches
KeywayAvailable in various keyways
MaterialSteel