SECURITRON MODEL MUNL-12, MUNL-24 MORTISE UNLATCH
INSTALLATION AND OPERATING INSTRUCTIONS
1. DESCRIPTION
Securitron’s Mortise UnLatch is a revolutionary new type of electric strike which eliminates the
necessity to perform a routing operation on the door frame for installation. The motor
driven Mortise UnLatch also presents a fully concealed appearance on the door which not
only enhances architectural appeal but improves security over a conventional electric strike as
an intruder is less able to determine the type of security device present on the door. The
Mortise UnLatch functions with all North American mortise locks and includes a latch
status output which reports when the door is in latched (secure) condition or is open.
Product Specifications are: Input Voltages: 12 VDC (MUNL-12), +20%, -10%. 24 VDC
(MUNL-24), +20%, -10%. Current: At rest: 40 mA (either voltage). When operating- 4 Amp
input surge @ 12 VDC; 2 Amp input surge @24 VDC for 100 milliseconds and 600 mA @ 12
VDC or 300 mA @ 24 VDC during motor movement. Operating Temperature: -10° to 125° F.
FIG 1: MORTISE UNLATCH DIMENSIONS (INCHES)
1.25
1.25
1.88
3.50
3.38
RECOMMENDED TOOLS
4.88
SPRINGLATCH
PLUNGER
DEADLATCH
FINGERS
MEDIUM + SMALL PHILLIPS DRIVER
MEDIUM SLOTTED DRIVER
CHISEL, 5/64 ALLEN WRENCH
WIRE CUTTER/STRIPPER
VOLT/OHM METER
CRIMP CONNECTORS
CRIMP PLIERS
2. PHYSICAL INSTALLATION
2.1 SURVEY
The installer must first be sure that the latch is of the mortise type
(see the drawing to the right.) A mortise lock (or latch) includes a
square shaped springlatch and a “pin” called the deadlatch pin or
guard bolt which may be positioned either above or below the
springlatch. Most mortise panic bar latches are also perfectly
compatible with the MUNL. Note, however, that if the mortise lock
assembly includes a dead bolt, the dead bolt will not be operable
The most common alternate type of latch in use in North America is
called cylindrical, tubular or bored. The standard UnLatch (model
numbers UNL-12 and UNL-24) is designed for this alternate type of
latch. Securitron does not offer an UnLatch solution for a rim latch
(rim latches are on the surface of the door rather than being mortised
into the middle of the door). Deadlatch Pin
Springlatch
Question and Answer IconNeed help?

Do you have a question about the Assa Abloy Door Lock and is the answer not in the manual?

Assa Abloy Door Lock Specifications

General IconGeneral
BrandASSA ABLOY
CategoryLocks
Power SupplyBattery
MaterialMetal
ConnectivityBluetooth, Wi-Fi

Summary

Mortise UnLatch Product Description

Mortise UnLatch Physical Installation Overview

Installation Survey and Lock Type Check

Initial check of door frame and lock type for compatibility with the Mortise UnLatch.

Steel Frame Installation for Mortise UnLatch

Wood Frame Installation for Mortise UnLatch

Mortise UnLatch Latch and Deadlatch Adjustment

Springlatch Plunger Location Determination

Procedure to align the springlatch plunger with the lock's springlatch for proper operation.

Springlatch Position Adjustment Procedure

Final Door Closing Tolerance Adjustment

Mortise UnLatch Operational Guide

Mortise UnLatch Wiring and Electrical Specs

Electrical Characteristics and Wiring

Details on voltage, current, and wiring requirements for the Mortise UnLatch.

Mortise UnLatch Wire Gauge Recommendations

Mortise UnLatch Latch Status Sensing

Magnacare Limited Lifetime Warranty

Mortise UnLatch Troubleshooting Common Issues

Troubleshooting: Unit Not Operating

Troubleshoot issues where the unit fails to respond to the trigger wire.

Troubleshooting: Occasional Operation Failure

Diagnose intermittent failures in the Mortise UnLatch operation.

Troubleshooting: Latch Re-secure Failure

Resolve problems where the latch does not properly re-secure after door closure.

Troubleshooting: Latch Status Sensing Failure

Troubleshoot the latch status sensing feature and its output.