D6061/D6071 Unitrol Double Unit Series
(Push Side) Power Operator
Installation Instructions
Tools Needed
1/4-20
#7
#2 and #3
10" or 12"
3/8
Punch
Set (Inch)
Supplied Fasteners per Operator
6061/6071
Union Assembly
(D6001U)
Union Spacer
(6001US)
End Cap - RH
(6001ENRH)
Closer Assembly
(7500LAP)
Operator LAP
(6021LAP)
Conduit Assembly
(D6001CON)
Power Module Sub-assembly
(6001PM)
Power Supply
(6000SUP)
Inverter
(6000IN)
End Cap - LH
(6001ENLH)
Union Spacer
(6001US)
Operator LAP
(6021LAP)
Inverter
(6000IN)
Power Supply
(6000SUP)
Power Module Sub-assembly
(6001PM)
Closer Assembly
(7500LAP)
Unitrol Arm
Standard Reveal
(6660-1) x2
Deep Reveal
(6670-1) x2
Pour la version francaise voir www.nortondoorcontrols.com.
READ AND FOLLOW ALL INSTRUCTIONS. SAVE THESE INSTRUCTIONS.
This product can expose you to lead which is known to the state of
California to cause cancer and birth defects or other reproductive harm.
For more information go to www.P65warnings.ca.gov.
WARNING
(D6001COV-36
D6001COV-38
D6001COV-40
D6001COV-42
D6001COV-44
D6001COV-46
D6001COV-48)
Backplate - LH
(D6001BP-36-RH
D6001BP-38-RH
D6001BP-40-RH
D6001BP-42-RH
D6001BP-44-RH
D6001BP-46-RH
D6001BP-48-RH)
Backplate - RH
Cover
(D6001BP-36-LH
D6001BP-38-LH
D6001BP-40-LH
D6001BP-42-LH
D6001BP-44-LH
D6001BP-46-LH
D6001BP-48-LH)
(D6001COV-36
D6001COV-38
D6001COV-40
D6001COV-42
D6001COV-44
D6001COV-46
D6001COV-48)

Questions and Answers

  • J
    James BrightSep 10, 2025
    What to do if Assa Abloy Norton D6061 opens before auxiliary components are unlatched?
    • B
      buchananjustinSep 12, 2025
      If, when a signal is received, your Assa Abloy Garage Door Opener tries to open the door before auxiliary components are unlatched or retracted: 1) Confirm the latch devices are getting proper power. 2) Confirm the latch devices are receiving power long enough to fully retract - adjust Latch Retraction on the controller as needed. 3) If the latch device is not retracting fast enough, increase the Start Delay on the controller to assure the latch device has had sufficient time to fully retract before the operator starts opening the door.
  • M
    Mr. Christopher PughAug 22, 2025
    What to do if Assa Abloy Garage Door Opener shows 'Under Voltage' error?
    • L
      Lauren WilsonAug 23, 2025
      If your Assa Abloy Garage Door Opener displays an “Under Voltage” error, it indicates that the incoming power line voltage has dropped below 80VAC. Check the incoming power supply.
  • W
    William BrooksAug 25, 2025
    What to do if Assa Abloy Garage Door Opener displays 'Short Circuit' error?
    • P
      pearsonchristopherAug 25, 2025
      If the Assa Abloy Garage Door Opener displays a “Short Circuit” error, turn off the power to the unit and check the wiring for any shorts or cuts.
  • S
    Shannon DanielsAug 26, 2025
    What to do if Assa Abloy Norton D6061 displays 'Drive Disabled' error?
    • M
      mackamyAug 27, 2025
      If the Assa Abloy Garage Door Opener displays a “Drive Disabled” error, the selector mode switch is likely in the “Off” position.
  • J
    jameshughesAug 28, 2025
    How to fix Assa Abloy Norton D6061 Garage Door Opener when door closing too fast?
    • D
      David HarrisAug 28, 2025
      If the door of your Assa Abloy Garage Door Opener is closing too fast, you can: 1) Adjust the Latch and/or Sweep valves on the closer clockwise; OR 2) Decrease the Closing Speed on the controller.
  • B
    Brianna LoganAug 29, 2025
    How to fix Assa Abloy Garage Door Opener when door closing too slow?
    • C
      cheyenne13Aug 29, 2025
      If the door of your Assa Abloy Garage Door Opener is closing too slowly, you can: 1) Adjust the Latch and/or Sweep valves on the closer counterclockwise; OR 2) Increase the Closing Speed on the controller.
  • T
    tylerlawrenceSep 18, 2025
    What to do if Assa Abloy Garage Door Opener displays 'Comm Error'?
    • N
      Nathan NicholsonSep 18, 2025
      If the Assa Abloy Garage Door Opener displays a “Comm Error”, the inverter must be replaced.
  • R
    Regina KramerSep 12, 2025
    Why Assa Abloy Norton D6061 Garage Door Opener cover will not snap onto backplate?
    • D
      Dylan SanchezSep 12, 2025
      If the cover of your Assa Abloy Garage Door Opener will not snap onto the backplate: 1) Check for wires protruding from under the cover. 2) Ensure the backplate is not twisted and is mounted properly.
  • R
    randolphmichaelSep 8, 2025
    How to stop Assa Abloy Norton D6061 door from drifting further open?
    • S
      scamachoSep 8, 2025
      If the door of your Assa Abloy Garage Door Opener drifts further open when it reaches the open position, decrease the Hold Speed on the controller until the door stops drifting.
  • N
    Nathan SinghSep 5, 2025
    How to stop Assa Abloy Norton D6061 door from bouncing when reaches open position?
    • C
      Christine MooreSep 5, 2025
      If the door of your Assa Abloy Garage Door Opener bounces when it reaches the open position, decrease the Slow Speed on the controller.

Summary

General Information and Preparation

Operation Overview

Describes operator modes, opening, closing cycles, and infinite hold open.

Before You Begin

Covers preparation steps, mounting hardware, and technical data.

Frame and Door Preparation

Frame Preparation

Details frame preparation requirements and measurements.

Backplate Mounting

Instructions for mounting backplates to the frame.

Door Preparation

Steps for preparing doors for adjusting tubes and shoes.

Operator Installation

Install End Caps and Operator LAP

Mounting end caps and the operator LAP to the backplates.

Install Conduit and Power Modules

Wiring conduit assembly and mounting power modules.

Connect Assemblies and Union

Connecting modules to LAPs and installing the union assembly.

Install Door Arms and Adjustments

Install Door Arms and Tubes

Attaching adjusting tubes and main arms to doors.

Adjust Mechanical Closer Features

Adjusting closer features and spring force for proper operation.

Configuration and Sync Operators

Power Operator Settings

Configuring home position and system settings via the controller.

Sync Operator Setup

Configuring master/follower units for double door operation.

Wiring and Final Installation

Final Covers and Electrical Info

Attaching covers, electrical practices, and wire sizing.

Double Door Wiring Diagrams

Key wiring configurations for various double door functions.

Advanced Features and Troubleshooting

Receiver User Guide

Operation and configuration of the 433MHz receiver.

Presence Detector Wiring

Installation and wiring for presence sensors.

Troubleshooting Guide

Common issues and their solutions for the power operator.

Assa Abloy Norton D6061 Series Specifications

General IconGeneral
BrandAssa Abloy
ModelNorton D6061 Series
CategoryGarage Door Opener
LanguageEnglish

Related product manuals