A - Power cable, 90-250V-50-60Hz
B - ON/OFF switch.
C - BNC connector for pH probe or Rx probe.
D - BNC connector for temperature probe.
E - Flow sensor connector (3 and 4 contacts).
F - Level probe connector (3 and 4 contacts).
DEFAULT SETTINGS
Language: French
PASSWORD = Not programmed
Delay On: 0 minutes
Broken Hose: active
TAL: 0 unit (disabled)
Flow: Normally Open
Temperature: 25°C
pH:
Dosing: Proportional
SetP (setpoint): 7.2 pH
T.MAX (maximum threshold):8.2pH
Flow.Max (maximum flowrate): 80%
Delay On: 3 sec (0-999sec)
Rx:
Dosing: Proportional
SetP (setpoint): 730mV
T.MAX (maximum threshold): 630mV
Flow.Max (maximum flowrate): 80%
Delay On: 3 sec (0-999sec)
DEFAULT SETTINGS RESTORE
3sec
Keep pushing for 3 seconds the ENTER / MENU button to
enter into the programming menu.
Move the cursor > to Utility by pressing . Push ENTER
button to enter the submenu.
Push button to move the cursor to “Reset”.
Push ENTER button to confirm.
By pushing the button choose “YES” to confirm and push
ENTER button.
Choose to restore the "Programming Parameters". Press
ENTER.
Automatically the pump restores the factory settings.
Press the ESC button for 3 seconds to exit programming.