SWIMMING POOL HEAT PUMP User and service manual
POMPE À CHALEUR POUR PISCINE Manuel d’installation et d’utilisation
ZWEMBAD WARMTEPOMP Gebruiker en service manual
BOMBA DE CALOR PARA PISCINA Manual del usuario y de servicio
SCHWIMMBAD - WÄRMEPUMPE Benutzer - und Wartungshandbuch
PISCINA POMPA DI CALORE Istruzioni per l'uso e di servizio
BOMBA DE CALOR DE PISCINA Manual do usuário e serviço
PRO ELYO INVERBOOST NN
EN
FR
NL
IT
ES
DE
PT

Questions and Answers

  • P
    peter74Sep 12, 2025
    What to do if my Astralpool Heat Pump has a gas return sensor failure?
    • H
      Heather DuranSep 13, 2025
      If your Astralpool Heat Pump shows a gas return sensor failure, it could be due to the sensor being in an open or short circuit, or the wiring of the sensor being loose. Check or change the sensor and re-fix the wiring of the sensors.
  • R
    Robin MillerAug 25, 2025
    What to do if my Astralpool PROELYXP09i Heat Pump shows a water flow failure TS1?
    • G
      Gregory MorenoAug 25, 2025
      If your Astralpool Heat Pump displays a water flow failure TS1, it could be due to a damaged water flow switch or insufficient water flow. Try replacing the water flow switch or checking the filtration pump and waterway system to ensure adequate water flow.
  • T
    Tammy SharpAug 25, 2025
    Why is my Astralpool PROELYXP09i showing compressor current protection?
    • L
      Lisa RodriguezAug 26, 2025
      Compressor current protection in your Astralpool Heat Pump can occur due to several reasons: the compressor current being too large instantaneously, incorrect connection for compressor phase sequence, compressor accumulations of liquid and oil, a damaged compressor or driver board, abnormal water flow, or power fluctuations. To resolve this, check the compressor, compressor phase, power range, phase sequence connection, the waterway system and filtration pump, and mains power input.
  • A
    April SchmidtSep 23, 2025
    What to do if my Astralpool PROELYXP09i has The inter-chip communication failure on the main control board?
    • J
      Jeff HernandezSep 23, 2025
      If your Astralpool Heat Pump experiences an inter-chip communication failure on the main control board, it indicates a main board failure. Turn off the electricity supply and restart it, or change the main board.
  • C
    Cheryl SmithSep 13, 2025
    What to do if my Astralpool Heat Pump has an ambient temperature sensor failure T5?
    • T
      Timothy HolmesSep 13, 2025
      If your Astralpool Heat Pump shows an ambient temperature sensor failure T5, it could be due to the sensor being in an open or short circuit, or the wiring of the sensor being loose. Check or change the sensor and re-fix the wiring of the sensors.
  • A
    Alexis BradshawSep 22, 2025
    What does compressor phase failure mean for my Astralpool PROELYXP09i?
    • T
      timothy85Sep 22, 2025
      Compressor phase failure in your Astralpool Heat Pump means that the compressors U, V, W are connected to one phase or two phases. Check the actual wiring according to the circuit diagram.
  • G
    Gina NixonSep 6, 2025
    What to do if my Astralpool PROELYXP09i Heat Pump shows IPM module temperature too high protection?
    • N
      nguyencarolSep 6, 2025
      If your Astralpool Heat Pump displays an IPM module temperature too high protection error, it could be due to an output exception of the IPM module thermal circuit, an abnormal or damaged motor, or a broken fan blade. Try changing the driver board, checking if the fan motor speed is too low or fan motor is damaged, or changing the fan blade.
  • J
    Joe MontgomerySep 7, 2025
    What causes PFC module protection in Astralpool PROELYXP09i?
    • N
      Nichole DavisSep 7, 2025
      PFC module protection in your Astralpool Heat Pump can be triggered by an output exception of the PFC module, an abnormal or damaged motor, a broken fan blade, or abnormal input power. To solve this, change the driver board, check if the motor speed is too low or fan motor is damaged, change the fan blade, or check the input voltage.
  • C
    charlesjonesSep 23, 2025
    What to do if my Astralpool PROELYXP09i Heat Pump has four-way valve reversal failure?
    • A
      Angela OchoaSep 23, 2025
      If your Astralpool Heat Pump experiences a four-way valve reversal failure, it may be due to the valve failing to reverse or a lack of refrigerant. Switch to cooling mode to check if the 4-way valve has been reversed correctly, change the 4-way valve, or fill with gas.
  • M
    morrisonjohnAug 30, 2025
    How to resolve communication failure between Main control board and Driving board in Astralpool Heat Pump?
    • D
      Debra SmithAug 31, 2025
      A communication failure between the Main control board and Driving board in your Astralpool Heat Pump is likely caused by a poor connection of the communication wire or a damaged wire. Check the wire connection and replace the wire if necessary.

Summary

1. Description

3. Specifications

Technical Data Tables

Presents detailed technical specifications and performance data.

General Data

Lists general technical specifications like compressor type, voltage, and current.

5. Location and Connection

5.1 Heat Pump Location

Guidelines for selecting the optimal installation location for the unit.

5.4 Initial Operation

Procedure for starting up the heat pump for the first time.

6. Electrical Wiring

7. Start-up of the Heat Pump

7.3 Heating Operation Logic

Details the logic for heating operation based on water temperature.

7.4 Cooling Operation Logic

Details the logic for cooling operation based on water temperature.

8. Troubleshooting

8.1 Error Code Display

Lists error codes, reasons, and solutions for controller displays.

Overheating;Overcooling Protection

Explains protection mechanisms for overheating and overcooling.

8.2 Other Malfunctions and Solutions

Addresses malfunctions without error codes on the controller.