SWIMMING POOL HEAT PUMP User and service manual
POMPE À CHALEUR POUR PISCINE Manuel d’installation et d’utilisation
ZWEMBAD WARMTEPOMP Gebruiker en service manual
BOMBA DE CALOR PARA PISCINA Manual del usuario y de servicio
SCHWIMMBAD - WÄRMEPUMPE Benutzer - und Wartungshandbuch
PISCINA POMPA DI CALORE Istruzioni per l'uso e di servizio
BOMBA DE CALOR DE PISCINA Manual do usuário e serviço
PRO ELYO INVERBOOST NN
EN
FR
NL
IT
ES
DE
PT

Questions and Answers

  • C
    Carmen DavisSep 1, 2025
    What does 'low ambient temperature protection' mean for my Astralpool Heat Pump?
    • C
      Christopher FrenchSep 1, 2025
      The 'low ambient temperature protection' message on your Astralpool Heat Pump indicates that the unit is either being used outside of its intended environment or that there is a sensor abnormality. Stop using the unit if it is beyond its operating scope, or change the sensor.
  • P
    peter74Sep 12, 2025
    What to do if my Astralpool Heat Pump has a gas return sensor failure?
    • H
      Heather DuranSep 13, 2025
      If your Astralpool Heat Pump shows a gas return sensor failure, it could be due to the sensor being in an open or short circuit, or the wiring of the sensor being loose. Check or change the sensor and re-fix the wiring of the sensors.
  • M
    morrisonjohnAug 30, 2025
    How to resolve communication failure between Main control board and Driving board in Astralpool Heat Pump?
    • D
      Debra SmithAug 31, 2025
      A communication failure between the Main control board and Driving board in your Astralpool Heat Pump is likely caused by a poor connection of the communication wire or a damaged wire. Check the wire connection and replace the wire if necessary.
  • R
    Roy WashingtonSep 15, 2025
    What should I do if my Astralpool PROELYXP09i shows an input power failure?
    • M
      Michele CuevasSep 15, 2025
      If your Astralpool Heat Pump indicates an input power failure, it's likely due to supply voltage fluctuations. Check whether the voltage is stable.
  • D
    dennisphillipsSep 14, 2025
    What to do if my Astralpool PROELYXP09i Heat Pump has an exhaust piping sensor failure T6?
    • A
      Angela MorrisonSep 14, 2025
      If your Astralpool Heat Pump shows an exhaust piping sensor failure T6, it could be due to the sensor being in an open or short circuit, or the wiring of the sensor being loose. Check or change the sensor and re-fix the wiring of the sensors.
  • A
    Alexis BradshawSep 22, 2025
    What does compressor phase failure mean for my Astralpool PROELYXP09i?
    • T
      timothy85Sep 22, 2025
      Compressor phase failure in your Astralpool Heat Pump means that the compressors U, V, W are connected to one phase or two phases. Check the actual wiring according to the circuit diagram.
  • M
    Marissa BrownAug 27, 2025
    How to fix communication failure between controller and main board in Astralpool PROELYXP09i Heat Pump?
    • M
      Manuel BurkeAug 27, 2025
      A communication failure between the controller and main board of your Astralpool Heat Pump is often due to a poor signal wire connection, a damaged signal wire, or a controller malfunction. Check and reconnect the signal wire, replace the signal wire, turn off the electricity supply and restart the machine, or replace the controller.
  • J
    Justin BrownAug 27, 2025
    What to do if my Astralpool Heat Pump displays a low pressure failure TS5?
    • K
      Kathy NealAug 27, 2025
      If your Astralpool Heat Pump is showing a low pressure failure TS5, it could be caused by a blocked EEV or jammed pipe system, abnormal motor speed or motor damage, or gas leakage. You should check the EEV and piping system, check the motor, use a high-pressure gauge to check the pressure value and check the refrigeration system.
  • B
    Brenda SimmonsAug 26, 2025
    What causes T6 exhaust too high protection in Astralpool PROELYXP09i Heat Pump?
    • T
      Toni HillAug 26, 2025
      T6 exhaust too high protection in your Astralpool Heat Pump can result from a lack of gas, low water flow, a blocked piping system, or a faulty exhaust temperature sensor. Address this by checking the high-pressure gauge and filling with gas if needed, inspecting the waterway system and filtration pump, checking the piping system for blockages, and replacing the exhaust temperature sensor.
  • T
    Tammy SharpAug 25, 2025
    Why is my Astralpool PROELYXP09i showing compressor current protection?
    • L
      Lisa RodriguezAug 26, 2025
      Compressor current protection in your Astralpool Heat Pump can occur due to several reasons: the compressor current being too large instantaneously, incorrect connection for compressor phase sequence, compressor accumulations of liquid and oil, a damaged compressor or driver board, abnormal water flow, or power fluctuations. To resolve this, check the compressor, compressor phase, power range, phase sequence connection, the waterway system and filtration pump, and mains power input.

Summary

1. Description

3. Specifications

Technical Data Tables

Presents detailed technical specifications and performance data.

General Data

Lists general technical specifications like compressor type, voltage, and current.

5. Location and Connection

5.1 Heat Pump Location

Guidelines for selecting the optimal installation location for the unit.

5.4 Initial Operation

Procedure for starting up the heat pump for the first time.

6. Electrical Wiring

7. Start-up of the Heat Pump

7.3 Heating Operation Logic

Details the logic for heating operation based on water temperature.

7.4 Cooling Operation Logic

Details the logic for cooling operation based on water temperature.

8. Troubleshooting

8.1 Error Code Display

Lists error codes, reasons, and solutions for controller displays.

Overheating;Overcooling Protection

Explains protection mechanisms for overheating and overcooling.

8.2 Other Malfunctions and Solutions

Addresses malfunctions without error codes on the controller.